Title: | Modelling for simplifying hydraulic design procedure of drop inlet spillway |
Other Titles: | Not Available |
Authors: | Satyendra Kumar N N Sirothia Ashwani Kumar |
ICAR Data Use Licennce: | http://krishi.icar.gov.in/PDF/ICAR_Data_Use_Licence.pdf |
Author's Affiliated institute: | ICAR-Central Soil Salinity Research Institute, Karnal Allahabad Agricultural Institute (Deemed University), Allahabad, India |
Published/ Complete Date: | 2006 |
Project Code: | Not Available |
Keywords: | gully control structure |
Publisher: | ISAE |
Citation: | Kumar, Satyendra, Ashwani Kumar, and N. N. Sirothia. "Modelling for Simplifying Hydraulic Design Procedure of Drop Inlet Spillway." Journal of Agricultural Engineering 43, no. 2 (2006): 41-44. |
Series/Report no.: | Not Available; |
Abstract/Description: | Models were developed to determine the hydraulic design dimension of drop inlet structure. The kinetic energy and drop of flowing water were taken as independent variables. The kinetic energy was estimated from the design discharges and drops of the structures made by Department of Soil Conservation, Government of Uttar Pradesh. Coefficient of determination (R2) of estimate of the models was 0.9907 and 0.9998 respectively for diameter and length of drop inlet pipe. The predicated (model) values were in close agreement with standard design values. The models estimated hydraulic design values within ± 7 and 3% accuracy level for diameter and length of drop inlet pipe, respectively. The Students t-test between standard procedure and models values indicated that model estimate were at par with standard values at 0.01% significance level. |
Description: | Not Available |
ISSN: | Not Available |
Type(s) of content: | Research Paper |
Sponsors: | Not Available |
Language: | English |
Name of Journal: | Journal of Agricultural Engineering (ISAE) |
NAAS Rating: | 4.79 |
Volume No.: | 43(2) |
Page Number: | 41-44 |
Name of the Division/Regional Station: | Division of Irrigation and Drainage Engineering |
Source, DOI or any other URL: | Not Available |
URI: | http://krishi.icar.gov.in/jspui/handle/123456789/25599 |
Appears in Collections: | NRM-CSSRI-Publication |
Files in This Item:
There are no files associated with this item.
Items in KRISHI are protected by copyright, with all rights reserved, unless otherwise indicated.