KRISHI
ICAR RESEARCH DATA REPOSITORY FOR KNOWLEDGE MANAGEMENT
(An Institutional Publication and Data Inventory Repository)
"Not Available": Please do not remove the default option "Not Available" for the fields where metadata information is not available
"1001-01-01": Date not available or not applicable for filling metadata infromation
"1001-01-01": Date not available or not applicable for filling metadata infromation
Please use this identifier to cite or link to this item:
http://krishi.icar.gov.in/jspui/handle/123456789/37329
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Mathala Juliet Gupta | en_US |
dc.contributor.author | Dr. Pitam Chandra | en_US |
dc.date.accessioned | 2020-06-20T10:13:06Z | - |
dc.date.available | 2020-06-20T10:13:06Z | - |
dc.date.issued | 2002-09-01 | - |
dc.identifier.citation | Not Available | en_US |
dc.identifier.issn | 0360-5442 | - |
dc.identifier.uri | http://krishi.icar.gov.in/jspui/handle/123456789/37329 | - |
dc.description | Not Available | en_US |
dc.description.abstract | A mathematical model was developed and used to study the effect of various energy conservation measures to arrive at a set of design features for an energy efficient greenhouse. The Simulation results indicated that under cold climatic conditions of northern India, a gothic arch shaped greenhouse required 2.6% and 4.2% less heating as compared to gable and quonset shapes. An east–west oriented gothic arch greenhouse required 2% less heating as compared to a north–south oriented one. North wall insulation of an east west oriented gothic arch greenhouse saved 30% in heating costs. The use of night curtains reduced the night time heating requirement by 70.8% and daily requirement by 60.6%. By replacing the single cover on the southern side with air inflated double wall glazing, the heating requirement was reduced by 23%. The combination of the design features for an energy efficient greenhouse suitable for cold climatic conditions was found to reduce the greenhouse heating needs by 80%. An internal rock bed thermal storage/retrieval system met the remaining heating energy requirements of the energy-conserving greenhouse. | en_US |
dc.description.sponsorship | Not Available | en_US |
dc.language.iso | English | en_US |
dc.publisher | Elsevier Science Ltd. | en_US |
dc.relation.ispartofseries | Not Available; | - |
dc.subject | greenhouse design, energy conservation, environment, control | en_US |
dc.title | Effect of greenhouse design parameters on conservation of energy for greenhouse environmental control | en_US |
dc.title.alternative | Not Available | en_US |
dc.type | Research Paper | en_US |
dc.publication.projectcode | Not Available | en_US |
dc.publication.journalname | Energy | en_US |
dc.publication.volumeno | 27 (8) | en_US |
dc.publication.pagenumber | 777–794 | en_US |
dc.publication.divisionUnit | Not Available | en_US |
dc.publication.sourceUrl | https://doi.org/10.1016/S0360-5442(02)00030-0. (http://www.sciencedirect.com/science/article/pii/S0360544202000300) | en_US |
dc.publication.authorAffiliation | ICAR::Central Coastal Agricultural Research Institute | en_US |
dc.ICARdataUseLicence | http://krishi.icar.gov.in/PDF/ICAR_Data_Use_Licence.pdf | en_US |
dc.publication.naasrating | 12.08 | en_US |
Appears in Collections: | NRM-CCARI-Publication |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Effect-of-greenhouse-design-parameters-on-conservation-of-energy-fo_2002_Ene.pdf | 146.81 kB | Adobe PDF | View/Open |
Items in KRISHI are protected by copyright, with all rights reserved, unless otherwise indicated.