KRISHI
ICAR RESEARCH DATA REPOSITORY FOR KNOWLEDGE MANAGEMENT
(An Institutional Publication and Data Inventory Repository)
"Not Available": Please do not remove the default option "Not Available" for the fields where metadata information is not available
"1001-01-01": Date not available or not applicable for filling metadata infromation
"1001-01-01": Date not available or not applicable for filling metadata infromation
Please use this identifier to cite or link to this item:
http://krishi.icar.gov.in/jspui/handle/123456789/47104
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Paul A | en_US |
dc.contributor.author | Khan Z | en_US |
dc.contributor.author | Bhattacharyya A | en_US |
dc.contributor.author | Majumder S | en_US |
dc.contributor.author | Banerjee K | en_US |
dc.date.accessioned | 2021-06-01T09:08:31Z | - |
dc.date.available | 2021-06-01T09:08:31Z | - |
dc.date.issued | 2021-05-14 | - |
dc.identifier.citation | Not Available | en_US |
dc.identifier.issn | Not Available | - |
dc.identifier.uri | http://krishi.icar.gov.in/jspui/handle/123456789/47104 | - |
dc.description | Not Available | en_US |
dc.description.abstract | Public exposure to pesticides through tobacco has attracted serious attention. Here we report a simultaneous screening and quantitation method for the non-target multiresidue analysis of pesticides in different tobacco types. The method involved extraction of a homogenate (20 g, containing 2 g tobacco) in ethyl acetate (10 mL), cleanup of 2 mL extract by dispersive solid phase extraction with PSA (50 mg)+C18 (50 mg)+GCB (25 mg)+MgSO4 (100 mg), followed by reconstitution in 1 mL acetonitrile:water (3:7) and analysis using HPLC with Quadrupole-Orbitrap mass spectrometry. The high resolution accurate mass analysis was performed through sequential full-scan (resolution=35000) and variable data independent acquisition (resolution=17500) events. When the method was evaluated in a mixture of 181 pesticides, it effectively minimised matrix interferences and false negatives. The target compounds included 5 pairs of isomers and 27 pairs of isobars, which were distinguished based on chromatographic separation, mass resolving power and/or unique product ions. The screening detection limit (SDL) for 86.4% of the test pesticides was set at 5 ng/g, while the remainder had the SDLs at 10 ng/g (9.3%) and 40 ng/g (4.3%). Nearly, 75% of the compounds showed recoveries of 70–120% at 10 ng/g. The rest of the compounds showed satisfactory recoveries at 40 and 100 ng/g. In all cases, precision-RSDs were < 20%. The established method demonstrated a successful performance in four different types of tobacco matrices while aligning with the guidelines of SANTE and US-FDA. Owing to its efficiency, the method is recommended for screening and quantitation of multiclass pesticides in tobacco. | en_US |
dc.description.sponsorship | Not Available | en_US |
dc.language.iso | English | en_US |
dc.relation.ispartofseries | Not Available; | - |
dc.subject | Multiresidue analysis of pesticides in tobacco | en_US |
dc.subject | Quadrupole-Orbitrap mass spectrometry | en_US |
dc.subject | High resolution accurate mass analysis | en_US |
dc.subject | Screening detection limit | en_US |
dc.title | Multiclass pesticide residue analysis in tobacco (Nicotiana tabacum) using high performance liquid chromatography-high resolution (Orbitrap) mass spectrometry: A simultaneous screening and quantitative method | en_US |
dc.title.alternative | Not Available | en_US |
dc.type | Research Paper | en_US |
dc.publication.projectcode | Not Available | en_US |
dc.publication.journalname | Journal of Chromatography A | en_US |
dc.publication.volumeno | 1648 | en_US |
dc.publication.pagenumber | Not Available | en_US |
dc.publication.divisionUnit | Crop Chemistry & Soil Science, Agricultural Chemicals | en_US |
dc.publication.sourceUrl | https://doi.org/10.1016/j.chroma.2021.462208 | en_US |
dc.publication.authorAffiliation | ICAR::Central Tobacco Research Institute | en_US |
dc.publication.authorAffiliation | ICAR::Indian Institute of Vegetable Research | en_US |
dc.publication.authorAffiliation | ICAR::National Research Centre for Grapes | en_US |
dc.ICARdataUseLicence | http://krishi.icar.gov.in/PDF/ICAR_Data_Use_Licence.pdf | en_US |
dc.publication.naasrating | 10.05 | en_US |
dc.publication.impactfactor | 4.05 | en_US |
Appears in Collections: | CS-CTRI-Publication |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Orbitrap_tobacco_JCA.pdf | 1.73 MB | Adobe PDF | View/Open |
Items in KRISHI are protected by copyright, with all rights reserved, unless otherwise indicated.