KRISHI
ICAR RESEARCH DATA REPOSITORY FOR KNOWLEDGE MANAGEMENT
(An Institutional Publication and Data Inventory Repository)
"Not Available": Please do not remove the default option "Not Available" for the fields where metadata information is not available
"1001-01-01": Date not available or not applicable for filling metadata infromation
"1001-01-01": Date not available or not applicable for filling metadata infromation
Please use this identifier to cite or link to this item:
http://krishi.icar.gov.in/jspui/handle/123456789/56353
Title: | Evaluation of hydraulic energy nozzle suitable for low velocity air-assisted sprayer |
Other Titles: | Not Available |
Authors: | Syed Imran S |
ICAR Data Use Licennce: | http://krishi.icar.gov.in/PDF/ICAR_Data_Use_Licence.pdf |
Author's Affiliated institute: | ICAR::Central Institute of Agricultural Engineering |
Published/ Complete Date: | 2018-01-10 |
Project Code: | Not Available |
Keywords: | Air-assisted, Droplet size, Hydraulic nozzle, Knapsack sprayer, Pesticide |
Publisher: | Not Available |
Citation: | Not Available |
Series/Report no.: | Not Available; |
Abstract/Description: | Performance evaluation of commercially available hydraulic energy nozzles (HCN/PB, HCN/PC, HCN/PD and HCN/PE) used in manually operated sprayer was conducted to identify the suitable nozzle for low velocity air-assisted sprayer. The discharge rate, droplet size, droplet size distribution pattern and spray distribution pattern of all the types of nozzles were measured with a pressure range of 0.1 to 0.4 MPa at an interval of 0.1 MPa. It was found that with the increase in pressure from 0.1 to 0.4 MPa, the discharge rate, swath width and spray angle increased for all the four types of nozzles. At all working pressures, the discharge rate and spray width is higher for HCN/PE nozzle followed by HCN/PD, HCN/PC and HCN/PB. The discharge rate of HCN/PB nozzle (363 to 533 ml/min) was found suitable for cotton crop. For the tested pressure range (0.1 to 0.4 MPa), the HCN/PB nozzle produces best droplet size in between 100 to 150 μm, good uniformity coefficient and the maximum percentage (63.81, 64.65, 61.56 and 65.5 per cent) of volume of the droplets at 100 to 200 μm. |
Description: | Not Available |
ISSN: | Not Available |
Type(s) of content: | Research Paper |
Sponsors: | Not Available |
Language: | English |
Name of Journal: | Not Available |
Volume No.: | Not Available |
Page Number: | Not Available |
Name of the Division/Regional Station: | Not Available |
Source, DOI or any other URL: | https://doi.org/10.20546/ijcmas.2018.701.171 |
URI: | http://krishi.icar.gov.in/jspui/handle/123456789/56353 |
Appears in Collections: | AEng-CIAE-Publication |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
3.IJCMAS.pdf | 488.61 kB | Adobe PDF | View/Open |
Items in KRISHI are protected by copyright, with all rights reserved, unless otherwise indicated.