KRISHI
ICAR RESEARCH DATA REPOSITORY FOR KNOWLEDGE MANAGEMENT
(An Institutional Publication and Data Inventory Repository)
"Not Available": Please do not remove the default option "Not Available" for the fields where metadata information is not available
"1001-01-01": Date not available or not applicable for filling metadata infromation
"1001-01-01": Date not available or not applicable for filling metadata infromation
Please use this identifier to cite or link to this item:
http://krishi.icar.gov.in/jspui/handle/123456789/34550
Title: | LC-MS/MS method optimization and validation for trace-level analysis of 71 crop protection chemicals in pulses |
Other Titles: | Not Available |
Authors: | Tirthankar Banerjee Suman Gupta Bijendra Singh Neethu Narayanan |
ICAR Data Use Licennce: | http://krishi.icar.gov.in/PDF/ICAR_Data_Use_Licence.pdf |
Author's Affiliated institute: | ICAR::Indian Agricultural Research Institute |
Published/ Complete Date: | 2019-10-09 |
Project Code: | Not Available |
Keywords: | Multiresidue method LC-MS/MS QuEChERS Pulses Insecticides Fungicides Herbicides |
Publisher: | Environmental Monitoring and Assessment, Springer Nature Switzerland AG |
Citation: | Environ Monit Assess (2019) 191:670 https://doi.org/10.1007/s10661-019-7859-4 |
Series/Report no.: | Not Available; |
Abstract/Description: | An analytical method involving modified QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) technique coupled with LC-MS/MS (Liquid Chromatography-tandem Mass Spectroscopy) has been developed for simultaneous identification and quantification of 71 pesticides [insecticides/acaricides/nematicides (32), fungicides (12), herbicides (26), plant growth regulator (1)] in different pulses (edible seeds of leguminous plants) namely gram, lentil, black gram and pea. The analysis was done using Shimadzu LC-MS/MS-8030 instrument equipped with Zorbax Eclipse Plus C-18 column operating under Electrospray Ionization (ESI) in positive and negative modes. Validation of method was done as per a single laboratory validation approach. Nine-point linear calibration curves for each pesticide were obtained in the range of 0.005 to 2 µg/g with correlation coefficient of ≥0.98. Limit of detection (LOD) for all the pesticides was achieved in the range of 0.001 -0.015 µg/g whereas the limit of quantification (LOQ) were found in the range of 0.01-0.05 µg/g. Recovery studies were conducted at 0.01 and 0.05 µg/g level of fortification using modified buffered QuEChERS method standardised for low moisture foods. It was observed that due to matrix interference, only around 75% of the pesticides were recovered in an acceptable range of 70-120% when compared against the solvent standard. With matrix-matched standards, 95% of the recovery results came within acceptable range with highly acceptable HorRat ratio (between 0.2 to 0.8) indicating satisfactory precision. The Global and Expanded Uncertainties for estimation of each pesticide in above mentioned pulse matrices were calculated to evaluate the suitability of the developed method for quantification of pesticides in pulse matrices.Not Available |
ISSN: | Not Available |
Type(s) of content: | Research Paper |
Sponsors: | Not Available |
Language: | English |
Name of Journal: | Environmental Monitoring and Assessment |
NAAS Rating: | 7.9 |
Volume No.: | 191 |
Page Number: | 670 (1-20) |
Name of the Division/Regional Station: | Agricultural Chemicals |
Source, DOI or any other URL: | https://doi.org/10.1007/s10661-019-7859-4 https://link.springer.com/article/10.1007/s10661-019-7859-4 |
URI: | http://krishi.icar.gov.in/jspui/handle/123456789/34550 |
Appears in Collections: | CS-IARI-Publication |
Files in This Item:
There are no files associated with this item.
Items in KRISHI are protected by copyright, with all rights reserved, unless otherwise indicated.