KRISHI
ICAR RESEARCH DATA REPOSITORY FOR KNOWLEDGE MANAGEMENT
(An Institutional Publication and Data Inventory Repository)
"Not Available": Please do not remove the default option "Not Available" for the fields where metadata information is not available
"1001-01-01": Date not available or not applicable for filling metadata infromation
"1001-01-01": Date not available or not applicable for filling metadata infromation
Please use this identifier to cite or link to this item:
http://krishi.icar.gov.in/jspui/handle/123456789/41168
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | D. B. Shakyawar | en_US |
dc.contributor.author | V. Kadam | en_US |
dc.contributor.author | A. K. Surya | en_US |
dc.contributor.author | A. Ahmed | en_US |
dc.contributor.author | P. K. Pareek | en_US |
dc.contributor.author | P. Temani | en_US |
dc.date.accessioned | 2020-09-11T07:06:38Z | - |
dc.date.available | 2020-09-11T07:06:38Z | - |
dc.date.issued | 2013-09-11 | - |
dc.identifier.citation | Shakyawar, D. B., Kadam, V., Surya, A. K., Ahmed, A., Pareek, P. K., & Temani, P. (2013). Precise measurement of wool fibre diameter using computerized projection microscope. Indian Journal of Small Ruminants (The), 19(2), 190-192. | en_US |
dc.identifier.issn | Not Available | - |
dc.identifier.uri | http://krishi.icar.gov.in/jspui/handle/123456789/41168 | - |
dc.description | Not Available | en_US |
dc.description.abstract | A study was conducted to measure wool fibre diameter and medullation using advanced computerised projection microscope with image analysis software and results were compared with conventional microscope method. The variations in fibre diameter measured by two methods were significant at 5% level. However, the standard deviation and coefficient of variation of fibre diameter was lower for computerized microscope system than conventional microscope method. The new system provides quicker, reproducible results and requires less manpower as compared to conventional system. | en_US |
dc.description.sponsorship | ICAR-CSWRI | en_US |
dc.language.iso | English | en_US |
dc.publisher | Indian Society for Sheep and Goat Production and Utilization | en_US |
dc.relation.ispartofseries | Not Available; | - |
dc.subject | Image analysis | en_US |
dc.subject | Medullation | en_US |
dc.subject | Projection microscope | en_US |
dc.subject | Wool fibre | en_US |
dc.title | Precise wool fibre diameter measurement using a computerized projection microscope | en_US |
dc.title.alternative | Not Available | en_US |
dc.type | Research Paper | en_US |
dc.publication.projectcode | Not Available | en_US |
dc.publication.journalname | The Indian Journal of Small Ruminants | en_US |
dc.publication.volumeno | 19 (2) | en_US |
dc.publication.pagenumber | 190-192 | en_US |
dc.publication.divisionUnit | Textile Manufacturing and Textile Chemistry Division, ICAR- CSWRI | en_US |
dc.publication.sourceUrl | http://www.indianjournals.com/ijor.aspx?target=ijor:ijsr&volume=19&issue=2&article=015 | en_US |
dc.publication.authorAffiliation | Shakyawar, D. B., Kadam, V., Surya, A. K., Ahmed, A., Pareek, P. K., & Temani, P. (2013). Precise measurement of wool fibre diameter using computerized projection microscope. Indian Journal of Small Ruminants (The), 19(2), 190-192. | en_US |
dc.ICARdataUseLicence | http://krishi.icar.gov.in/PDF/ICAR_Data_Use_Licence.pdf | en_US |
dc.publication.naasrating | 5.95 | en_US |
Appears in Collections: | AS-CSWRI-Publication |
Files in This Item:
There are no files associated with this item.
Items in KRISHI are protected by copyright, with all rights reserved, unless otherwise indicated.