KRISHI
ICAR RESEARCH DATA REPOSITORY FOR KNOWLEDGE MANAGEMENT
(An Institutional Publication and Data Inventory Repository)
"Not Available": Please do not remove the default option "Not Available" for the fields where metadata information is not available
"1001-01-01": Date not available or not applicable for filling metadata infromation
"1001-01-01": Date not available or not applicable for filling metadata infromation
Please use this identifier to cite or link to this item:
http://krishi.icar.gov.in/jspui/handle/123456789/47064
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | D.B. Shakyawar, Vinod Kadam, A.K. Zurya, Aziz Ahmed, P.K. Pareek and Priyanka Temani | en_US |
dc.date.accessioned | 2021-05-26T09:36:33Z | - |
dc.date.available | 2021-05-26T09:36:33Z | - |
dc.date.issued | 2012-12-24 | - |
dc.identifier.citation | Not Available | en_US |
dc.identifier.issn | Not Available | - |
dc.identifier.uri | http://krishi.icar.gov.in/jspui/handle/123456789/47064 | - |
dc.description | Not Available | en_US |
dc.description.abstract | Astudy was conducted to measure wool fibre diameter and medullation using advanced computerised projection microscope with image analysis software and results were compared with conventional microscope method. The variations in fibre diameter measured by two methods were significant at 5% level. However, the standard deviation and co-efficient of variation of fibre diameter was lower for computerised microscope system than conventional microscope method. The new system provides quicker, reproducible results and requires less manpower as compared to conventional system. | en_US |
dc.description.sponsorship | Not Available | en_US |
dc.language.iso | English | en_US |
dc.publisher | Not Available | en_US |
dc.relation.ispartofseries | Not Available; | - |
dc.subject | Image analysis, Medullation, Projection microscope, Woolfibre | en_US |
dc.title | Precise Measurement of Wool Fibre Diameter Using Computerized Projection Microscope | en_US |
dc.title.alternative | Not Available | en_US |
dc.type | Research Paper | en_US |
dc.publication.projectcode | Not Available | en_US |
dc.publication.journalname | Indian Journal of Small Ruminants | en_US |
dc.publication.volumeno | 19(2) | en_US |
dc.publication.pagenumber | 190-192 | en_US |
dc.publication.divisionUnit | Director | en_US |
dc.publication.sourceUrl | Not Available | en_US |
dc.publication.authorAffiliation | ICAR::National Institute of Research on Jute and Allied Fibre Technology | en_US |
dc.ICARdataUseLicence | http://krishi.icar.gov.in/PDF/ICAR_Data_Use_Licence.pdf | en_US |
dc.publication.naasrating | Not Available | - |
Appears in Collections: | AEng-NINFET-Publication |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
13-Precise Measurement of Wool Fibre Diameter Using Computerized Projection Microscope.pdf | 139.6 kB | Adobe PDF | View/Open |
Items in KRISHI are protected by copyright, with all rights reserved, unless otherwise indicated.