KRISHI
ICAR RESEARCH DATA REPOSITORY FOR KNOWLEDGE MANAGEMENT
(An Institutional Publication and Data Inventory Repository)
"Not Available": Please do not remove the default option "Not Available" for the fields where metadata information is not available
"1001-01-01": Date not available or not applicable for filling metadata infromation
"1001-01-01": Date not available or not applicable for filling metadata infromation
Please use this identifier to cite or link to this item:
http://krishi.icar.gov.in/jspui/handle/123456789/47085
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Zareen S. Khan, Rakesh Kumar Ghoshb, Rushali Girame, Sagar C. Utture, Manasi Gadgil, Kaushik Banerjee, D. Damodar Reddy, Nalli Johnson | en_US |
dc.date.accessioned | 2021-06-01T07:14:39Z | - |
dc.date.available | 2021-06-01T07:14:39Z | - |
dc.date.issued | 2014 | - |
dc.identifier.citation | Not Available | en_US |
dc.identifier.issn | Not Available | - |
dc.identifier.uri | http://krishi.icar.gov.in/jspui/handle/123456789/47085 | - |
dc.description | Not Available | en_US |
dc.description.abstract | A selective and sensitive multiresidue analysis method, comprising 4 7pesticides, was developed and validated in tobacco matrix. The optimized sample preparation procedure in combination with gas chromatography mass spectrometry in selected-ion-monitoring (GC-MS/SIM) mode offered limits of detection (LOD) and quantification (LOQ) in the range of 3–5 and 7.5–15 ng/g, respectively, with recoveries between 70 and 119% at 50–100 ng/g fortifications. In comparison to the modified QuEChERS (Quick-Easy- Cheap-Effective-Rugged-Safe method: 2 g tobacco + 10 ml water + 10 ml acetonitrile, 30 min vortexing, followed by dispersive solid phase extraction cleanup), the method performed better in minimizing matrix co-extractives e.g. nicotine and megastigmatrienone. Ambiguity in analysis due to co-elution of target analytes (e.g. transfluthrin-heptachlor) and with matrix co-extractives (e.g. -HCH-neophytadiene, 2,4-DDE-linolenic acid) could be resolved by selective multi-dimensional (MD)GC heart-cuts. The method holds promise in routine analysis owing to noticeable efficiency of 27 samples/person/day. | en_US |
dc.description.sponsorship | Not Available | en_US |
dc.language.iso | English | en_US |
dc.publisher | Elsevier | en_US |
dc.relation.ispartofseries | Not Available; | - |
dc.subject | Tobacco, Multiresidue analysis of pesticides, Matrix effect, GC-MS, MDGC-MS | en_US |
dc.title | Optimization of a sample preparation method for multiresidue analysis of pesticides in tobacco by single and multi-dimensional gas chromatography-mass spectrometry | en_US |
dc.title.alternative | Not Available | en_US |
dc.type | Journal | en_US |
dc.publication.projectcode | Not Available | en_US |
dc.publication.journalname | Journal of Chromatography - A | en_US |
dc.publication.volumeno | Not Available | en_US |
dc.publication.pagenumber | Not Available | en_US |
dc.publication.divisionUnit | Not Available | en_US |
dc.publication.sourceUrl | http://dx.doi.org/10.1016/j.chroma.2014.03.080 | en_US |
dc.publication.authorAffiliation | ICAR::National Institute of Research on Jute and Allied Fibre Technology | en_US |
dc.publication.authorAffiliation | ICAR::National Research Centre for Grapes | en_US |
dc.publication.authorAffiliation | ICAR::Central Tobacco Research Institute | en_US |
dc.ICARdataUseLicence | http://krishi.icar.gov.in/PDF/ICAR_Data_Use_Licence.pdf | en_US |
dc.publication.naasrating | 10.05 | en_US |
dc.publication.naasrating | 10.05 | - |
Appears in Collections: | AEng-NINFET-Publication |
Files in This Item:
There are no files associated with this item.
Items in KRISHI are protected by copyright, with all rights reserved, unless otherwise indicated.