KRISHI
ICAR RESEARCH DATA REPOSITORY FOR KNOWLEDGE MANAGEMENT
(An Institutional Publication and Data Inventory Repository)
"Not Available": Please do not remove the default option "Not Available" for the fields where metadata information is not available
"1001-01-01": Date not available or not applicable for filling metadata infromation
"1001-01-01": Date not available or not applicable for filling metadata infromation
Please use this identifier to cite or link to this item:
http://krishi.icar.gov.in/jspui/handle/123456789/51228
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ajit Nayak, K V Ramana Rao | en_US |
dc.date.accessioned | 2021-07-29T17:25:10Z | - |
dc.date.available | 2021-07-29T17:25:10Z | - |
dc.date.issued | 2014-09-20 | - |
dc.identifier.citation | Ajit Nayak, K V Ramana Rao. 2014. Estimation of wind load on a greenhouse and evaluation of its stability. International Journal of Agricultural Engineering. 7(2): 461-466. | en_US |
dc.identifier.issn | 0974-2662 | - |
dc.identifier.uri | http://krishi.icar.gov.in/jspui/handle/123456789/51228 | - |
dc.description | Not Available | en_US |
dc.description.abstract | Among all the loads that act on the greenhouse, wind load is the major one. In India, the basic wind speed varies from 33 to 55 m/s. Along with wind speed, wind load also depend on the geometry, height to width ratio, effective frontal area etc. So greenhouse design should be customized as per the localized wind load. ‘One size fits all approach’ in greenhouse design may leads to failure of the structure or being expensive. Unfortunately the standard for greenhouse design is lagging far behind in India. In this experiment, wind load for the double arch type naturally ventilated greenhouse was estimated as per IS code 875 (part 3) and IS 14462: 1997. The design wind pressure estimated to be 772 N/m2 and wind load on the roof of the greenhouse is 222 kN (Suction) and 185 kN (Pressure). A model of the greenhouse is developed by means simulation with Finite Element Method using ANSYS 15.0 to test its stability at the calculated wind load. The truss and columns are studied with deflections and failure zones diagrams and possible failures were found out to redesign the elements. | en_US |
dc.description.sponsorship | Not Available | en_US |
dc.language.iso | English | en_US |
dc.publisher | Not Available | en_US |
dc.relation.ispartofseries | Not Available; | - |
dc.subject | Wind load,Structural stability,FEM,Pressure co-efficient,Truss | en_US |
dc.title | Estimation of wind load on a greenhouse and evaluation of its structural stability | en_US |
dc.title.alternative | Not Available | en_US |
dc.type | Research Paper | en_US |
dc.publication.projectcode | Not Available | en_US |
dc.publication.journalname | International Journal of Agricultural Engineering | en_US |
dc.publication.volumeno | 7 (2) | en_US |
dc.publication.pagenumber | 461-466 | en_US |
dc.publication.divisionUnit | Not Available | en_US |
dc.publication.sourceUrl | 10.15740/HAS/IJAE/7.2/461-466 | en_US |
dc.publication.authorAffiliation | ICAR::Central Institute of Agricultural Engineering | en_US |
dc.ICARdataUseLicence | http://krishi.icar.gov.in/PDF/ICAR_Data_Use_Licence.pdf | en_US |
dc.publication.naasrating | 4.43 | en_US |
dc.publication.naasrating | Not Available | - |
Appears in Collections: | AEng-CIAE-Publication |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
7_461-466_A.pdf | 12.98 kB | Adobe PDF | View/Open |
Items in KRISHI are protected by copyright, with all rights reserved, unless otherwise indicated.