KRISHI
ICAR RESEARCH DATA REPOSITORY FOR KNOWLEDGE MANAGEMENT
(An Institutional Publication and Data Inventory Repository)
"Not Available": Please do not remove the default option "Not Available" for the fields where metadata information is not available
"1001-01-01": Date not available or not applicable for filling metadata infromation
"1001-01-01": Date not available or not applicable for filling metadata infromation
Please use this identifier to cite or link to this item:
http://krishi.icar.gov.in/jspui/handle/123456789/83890
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kaustav Aditya | en_US |
dc.contributor.author | Raju Kumar | en_US |
dc.contributor.author | Pankaj Das | en_US |
dc.date.accessioned | 2024-07-09T17:17:57Z | - |
dc.date.available | 2024-07-09T17:17:57Z | - |
dc.date.issued | 2024-05-20 | - |
dc.identifier.citation | Not Available | en_US |
dc.identifier.issn | Not Available | - |
dc.identifier.uri | http://krishi.icar.gov.in/jspui/handle/123456789/83890 | - |
dc.description | Not Available | en_US |
dc.description.abstract | The Calibration Approach proposed by Deville and Sarndal (1992) is one of the other techniques widely used for making efficient use of auxiliary information in survey estimation. Beyond the population parameters, there are sub-populations or domains for which estimates are needed to be generated now days. In this study, a domain calibration estimator for domain total were developed under two stage sampling design with assumptions of availability of auxiliary information at both PSU and SSU level of selection. The variance of the estimators and the corresponding variance estimators were also found. Both the proposed estimators were verified through limited simulation studies by generating an artificial population in R software. Various combinations of PSU and SSU sample sizes were drawn from each of the domains to draw the conclusions. Through the simulation study, it was found that all the proposed calibration estimators under two stage sampling design were performing at par with the Horvitz-Thompson estimator of the domain total under two stage sampling design with respect to the criteria of percent relative bias and performing consistently better than the HT estimator for the criteria of percent relative root mean square error. | en_US |
dc.description.sponsorship | ICAR-IASRI, New Delhi | en_US |
dc.language.iso | English | en_US |
dc.publisher | ICAR-IASRI, New Delhi | en_US |
dc.relation.ispartofseries | 1; | - |
dc.subject | Claibration Estimation | en_US |
dc.subject | Domain Estimation | en_US |
dc.subject | Two stage Sampling | en_US |
dc.title | A Study on Domain Calibration Estimators under Two Stage Sampling Design | en_US |
dc.title.alternative | Not Available | en_US |
dc.type | Project Report | en_US |
dc.publication.projectcode | AGEDIASRISIL202100100168 | en_US |
dc.publication.journalname | Not Available | en_US |
dc.publication.volumeno | Not Available | en_US |
dc.publication.pagenumber | Not Available | en_US |
dc.publication.divisionUnit | Division of Sample Surveys | en_US |
dc.publication.sourceUrl | Not Available | en_US |
dc.publication.authorAffiliation | ICAR-Indian Agricultural Statistics Research Institute, New Delhi | en_US |
dc.ICARdataUseLicence | http://krishi.icar.gov.in/PDF/ICAR_Data_Use_Licence.pdf | en_US |
dc.publication.journaltype | Not Available | en_US |
dc.publication.naasrating | Not Available | en_US |
dc.publication.impactfactor | Not Available | en_US |
Appears in Collections: | AEdu-IASRI-Publication |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Report 2024.pdf | 12.17 MB | Adobe PDF | View/Open |
Items in KRISHI are protected by copyright, with all rights reserved, unless otherwise indicated.