DC Field | Value | Language |
---|---|---|
dc.contributor.author | Saha A., Shabeer A.T.P., Banerjee Kaushik, Hingmire S., Bhaduri D., Jain N.K., Utture S. | en_US |
dc.date.accessioned | 2020-08-03T07:39:36Z | - |
dc.date.available | 2020-08-03T07:39:36Z | - |
dc.date.issued | 2014-07-14 | - |
dc.identifier.citation | Saha, A., Shabeer T. P., A., Banerjee, K. et al. Simultaneous analysis of herbicides pendimethalin, oxyfluorfen, imazethapyr and quizalofop-p-ethyl by LC–MS/MS and safety evaluation of their harvest time residues in peanut (Arachis hypogaea L.). J Food Sci Technol 52, 4001–4014 (2015). https://doi.org/10.1007/s13197-014-1473-9 | en_US |
dc.identifier.uri | https://doi.org/10.1007/s13197-014-1473-9 | - |
dc.identifier.uri | http://krishi.icar.gov.in/jspui/handle/123456789/38897 | - |
dc.description | Not Available | en_US |
dc.description.abstract | This paper reports a simple and rapid method for simultaneous determination of the residues of selected herbicides viz. pendimethalin, oxyfluorfen, imazethapyr and quizalofop-p-ethyl in peanut by liquid chromatography-tandem mass spectrometry (LC-MS/MS). A modified approach of the QuEChERS methodology was used to extract the herbicides from the peanut kernel without any clean-up. The method showed excellent linearity (r2 > 0.99) with no significant matrix effect. Accuracy of the method in terms of average recoveries of all the four herbicides ranged between 69.4 –94.4 % at spiking levels of 0.05, 0.10 and 0.25 mg kg−1 with intra-day and inter-day precision RSD (%) between 2.6–16.6 and 8.0–11.3, respectively. Limit of quantification (LOQs) was 5.0 μg kg−1 for pendimethalin, imazethapyr and quizalofop-p-ethyl and 10.0 μg kg−1 for oxyfluorfen. The expanded uncertainties were <11 % for determination of these herbicides in peanut. The proposed method was successfully applied for analysis of these herbicide residues in peanut samples harvested from the experimental field and the residues were below the detection level. | en_US |
dc.description.sponsorship | Not Available | en_US |
dc.language.iso | English | en_US |
dc.publisher | Springer | en_US |
dc.relation.ispartofseries | Not Available; | - |
dc.subject | Multiresidue analysis of pendimethalin, oxyfluorfen, imazethapyr and quizalofop-p-ethyl | en_US |
dc.subject | Peanut (Arachis hypogaea L.) | en_US |
dc.subject | LC-MS/MS | en_US |
dc.title | Simultaneous analysis of herbicides pendimethalin, oxyfluorfen, imazethapyr and quizalofop-p-ethyl by LC-MS/MS and safety evaluation of their harvest time residues in peanut (Arachis hypogaea L.) | en_US |
dc.title.alternative | Not Available | en_US |
dc.type | Journal | en_US |
dc.publication.projectcode | Not Available | en_US |
dc.publication.journalname | Journal of Food Science and Technology | en_US |
dc.publication.volumeno | 52 | en_US |
dc.publication.pagenumber | 4001-4014 | en_US |
dc.publication.divisionUnit | National Reference Laboratory | en_US |
dc.publication.sourceUrl | https://doi.org/10.1007/s13197-014-1473-9 | en_US |
dc.publication.authorAffiliation | ICAR::National Research Centre for Grapes | en_US |
dc.publication.authorAffiliation | ICAR::Directorate of Groundnut Research | en_US |
dc.ICARdataUseLicence | http://krishi.icar.gov.in/PDF/ICAR_Data_Use_Licence.pdf | en_US |
dc.publication.naasrating | 7.95 | en_US |
Appears in Collections: | HS-NRCG-Publication |
Files in This Item:
There are no files associated with this item.
Items in KRISHI are protected by copyright, with all rights reserved, unless otherwise indicated.