SIMPLIFIED EARTHQUAKE ANALYSIS OF INTAKE-OUTLET TOWERS
DSpace at IIT Bombay
View Archive InfoField | Value | |
Title |
SIMPLIFIED EARTHQUAKE ANALYSIS OF INTAKE-OUTLET TOWERS
|
|
Creator |
CHOPRA, AK
GOYAL, A |
|
Description |
A simplified procedure is presented to determine the maximum earthquake forces in intake-outlet towers directly from the design earthquake spectrum without the need for a response-history analysis. All the significant effects of tower-water interaction and tower-foundation-soil interaction are included in the analysis. The hydrodynamic effects of outside and inside water are approximately by added mass functions, which can be determined to a useful degree of accuracy without requiring regorous three-dimensional analysis of the two fluid domains. The simplified response spectrum analysis (SRSA) procedure utilizes convenient methods for computing: (1) The first two natural frequencies and modes of vibration of the tower; and (2) the modifications to the vibration period and the damping ratio of the fundamental vibration mode due to tower-foundation-soil interaction. The procedure is demonstrated to be accurate enough for preliminary design and safety evaluation of towers.
|
|
Publisher |
ASCE-AMER SOC CIVIL ENG
|
|
Date |
2011-07-18T10:39:14Z
2011-12-26T12:50:34Z 2011-12-27T05:35:59Z 2011-07-18T10:39:14Z 2011-12-26T12:50:34Z 2011-12-27T05:35:59Z 1991 |
|
Type |
Article
|
|
Identifier |
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 117(3), 767-788
0733-9445 http://dx.doi.org/10.1061/(ASCE)0733-9445(1991)117:3(767) http://dspace.library.iitb.ac.in/xmlui/handle/10054/4883 http://hdl.handle.net/10054/4883 |
|
Language |
en
|
|