Modeling of a coal-fired natural circulation boiler
DSpace at IIT Bombay
View Archive InfoField | Value | |
Title |
Modeling of a coal-fired natural circulation boiler
|
|
Creator |
BHAMBARE, KS
MITRA, SK GAITONDE, UN |
|
Subject |
mathematical-model
simulation natural circulation boiler drum downcomer waterwall furnace riser steady state transient |
|
Description |
Modeling of a natural circulation boiler for a coal-fired thermal power station is presented here. The boiler system is divided into seven subcomponents, and for each section, models based on conservation of mass, momentum, and energy are formulated. The pressure drop at various sections and the heat transfer coefficients are computed using empirical correlations. Solutions are obtained by using SIMULINK. The model is validated by comparing its steady state and dynamic responses with the actual plant data. Open loop responses of the model to the step changes in the operating parameters, such as pressure, temperature, steam flow, feed water flow, are also analyzed. The present model can be used for the development and design of effective boiler control systems.
|
|
Publisher |
ASME-AMER SOC MECHANICAL ENG
|
|
Date |
2011-07-18T18:25:42Z
2011-12-26T12:50:45Z 2011-12-27T05:36:49Z 2011-07-18T18:25:42Z 2011-12-26T12:50:45Z 2011-12-27T05:36:49Z 2007 |
|
Type |
Article
|
|
Identifier |
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 129(2), 159-167
0195-0738 http://dx.doi.org/10.1115/1.2719209 http://dspace.library.iitb.ac.in/xmlui/handle/10054/5015 http://hdl.handle.net/10054/5015 |
|
Language |
en
|
|