Temporal redundancy methods using risk-sensitive filtering and parameter estimation to detect failures in neutronic sensors during reactor start-up and steady-state operation
DSpace at IIT Bombay
View Archive InfoField | Value | |
Title |
Temporal redundancy methods using risk-sensitive filtering and parameter estimation to detect failures in neutronic sensors during reactor start-up and steady-state operation
|
|
Creator |
ROY, K
BANABAR, RN THANGASAMY, S |
|
Subject |
fault-detection
systems analytical redundancy kalman filtering log amplifier reactor-regulating system reactor start-up risk-sensitive filtering |
|
Description |
In this paper, simple linear single-input-single output models of the reactor-regulating system have been considered, and risk-sensitive filtering and risk-sensitive parameter-estimation techniques have been used to obtain temporal-redundancy relations. While a risk-sensitive filter is used to provide a temporally redundant measurement of reactivity from an analytically redundant process parameter during a reactor start-up, a risk-sensitive parameter estimation technique is used to obtain temporally redundant measurements during steady state operation.
|
|
Publisher |
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
|
|
Date |
2011-08-01T17:39:21Z
2011-12-26T12:53:27Z 2011-12-27T05:39:09Z 2011-08-01T17:39:21Z 2011-12-26T12:53:27Z 2011-12-27T05:39:09Z 2000 |
|
Type |
Article
|
|
Identifier |
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 47(6), 2706-2714