Experimental investigation on mixed refrigerant Joule-Thomson cryocooler with flammable and non-flammable refrigerant mixtures
DSpace at IIT Bombay
View Archive InfoField | Value | |
Title |
Experimental investigation on mixed refrigerant Joule-Thomson cryocooler with flammable and non-flammable refrigerant mixtures
|
|
Creator |
WALIMBE, NS
NARAYANKHEDKAR, KG ATREY, MD |
|
Subject |
gas-mixture
optimization cycle gas mixtures (b) joule-thomson cooler (e) |
|
Description |
The mixed refrigerant Joule-Thomson (MR J-T) cryocoolers have a wide application area covering the temperature range from 80 K to 200 K. The significant advantages of the system are simplicity of its design and working reliability with high level performance. The present paper discusses the experimental results of MR J-T cooler with different flammable and non-flammable mixture compositions. The work highlights the use of pressure-enthalpy and temperature-enthalpy diagrams for these mixtures to support the experimental results. A record lowest temperature of 65 K and a cooling capacity of 6 W at 80 K are obtained for a single stage MR J-T system starting at 300 K. Further, using a mixture of minimum flammable refrigerants, temperatures below 100 K is achieved.
|
|
Publisher |
ELSEVIER SCI LTD
|
|
Date |
2011-07-22T02:54:40Z
2011-12-26T12:52:16Z 2011-12-27T05:39:23Z 2011-07-22T02:54:40Z 2011-12-26T12:52:16Z 2011-12-27T05:39:23Z 2010 |
|
Type |
Article
|
|
Identifier |
CRYOGENICS, 50(10), 653-659
0011-2275 http://dx.doi.org/10.1016/j.cryogenics.2010.06.002 http://dspace.library.iitb.ac.in/xmlui/handle/10054/6083 http://hdl.handle.net/10054/6083 |
|