Record Details

Influence of reactor configuration on reliability of activated sludge process

DSpace at IIT Bombay

View Archive Info
 
 
Field Value
 
Title Influence of reactor configuration on reliability of activated sludge process
 
Creator SARNA, P
CHAUDHARI, S
 
Subject activated sludge process
uncertain kinetic parameter
reliability
mixed tank reactor
plug flow reactor
 
Description The effect of uncertainty in system parameters and the accuracy of the mathematical model used on the design and reliability of the activated sludge process is investigated by Monte Carlo simulations. Simulations indicate that the coefficient of variation for a reactor volume varies from 0.56 for a single mixed tank reactor to 0.44 for a plug flow reactor. The coefficient of variation for effluent for reactors designed on nominal values was found to be 0.56 for a mixed-tank reactor, 1.28 for two reactors in series, 1.56 for three reactors in series and 1.6 for a plug flow reactor. Significant contributing parameters to the reliability of the process are established. Reactor volumes for desired reliability levels are also calculated.
 
Publisher INDERSCIENCE ENTERPRISES LTD
 
Date 2011-08-01T20:33:34Z
2011-12-26T12:53:29Z
2011-12-27T05:39:37Z
2011-08-01T20:33:34Z
2011-12-26T12:53:29Z
2011-12-27T05:39:37Z
2006
 
Type Article
 
Identifier INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 26(4), 364-378
0957-4352
http://dspace.library.iitb.ac.in/xmlui/handle/10054/8538
http://hdl.handle.net/10054/8538
 