Influence of reactor configuration on reliability of activated sludge process
DSpace at IIT Bombay
View Archive InfoField | Value | |
Title |
Influence of reactor configuration on reliability of activated sludge process
|
|
Creator |
SARNA, P
CHAUDHARI, S |
|
Subject |
activated sludge process
uncertain kinetic parameter reliability mixed tank reactor plug flow reactor |
|
Description |
The effect of uncertainty in system parameters and the accuracy of the mathematical model used on the design and reliability of the activated sludge process is investigated by Monte Carlo simulations. Simulations indicate that the coefficient of variation for a reactor volume varies from 0.56 for a single mixed tank reactor to 0.44 for a plug flow reactor. The coefficient of variation for effluent for reactors designed on nominal values was found to be 0.56 for a mixed-tank reactor, 1.28 for two reactors in series, 1.56 for three reactors in series and 1.6 for a plug flow reactor. Significant contributing parameters to the reliability of the process are established. Reactor volumes for desired reliability levels are also calculated.
|
|
Publisher |
INDERSCIENCE ENTERPRISES LTD
|
|
Date |
2011-08-01T20:33:34Z
2011-12-26T12:53:29Z 2011-12-27T05:39:37Z 2011-08-01T20:33:34Z 2011-12-26T12:53:29Z 2011-12-27T05:39:37Z 2006 |
|
Type |
Article
|
|
Identifier |
INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 26(4), 364-378
0957-4352 http://dspace.library.iitb.ac.in/xmlui/handle/10054/8538 http://hdl.handle.net/10054/8538 |
|
Language |
en
|
|