Record Details

Local heat transfer distribution in a square channel with 90 degrees continuous, 90 degrees saw tooth profiled and 60 degrees broken ribs

DSpace at IIT Bombay

View Archive Info
 
 
Field Value
 
Title Local heat transfer distribution in a square channel with 90 degrees continuous, 90 degrees saw tooth profiled and 60 degrees broken ribs
 
Creator GUPTA, A
SRIHARSHA, V
PRABHU, SV
VEDULA, RP
 
Subject rectangular channels
parallel
heat transfer enhancement
90 degrees continuous ribs
90 degrees profiled ribs
v-broken ribs
thin metal foil technique
 
Description Internal channel cooling is employed in advanced gas turbines blade to allow high inlet temperatures so as to achieve high thrust/weight ratios and low specific fuel consumption. The objective of the present study is to measure the local heat transfer distributions in a double wall ribbed square channel with 90 degrees continuous, 90 degrees saw tooth profiled and 60 degrees V-broken ribs. Comparison is made between the 90 degrees continuous ribs (Ple = 7 and 10 for a elD = 0.15) and 90 degrees saw tooth profiled rib configurations (Ple = 7 for an elD = 0.15) for the same rib height to the hydraulic diameter ratio (elD). The effect of pitch to rib height ratio (Ple = 7.5,10 and 12) of 60 degrees V-broken ribbed channel with a constant rib height to hydraulic diameter ratio (elD) of 0.0625 on the local heat transfer distribution is studied. The Reynolds number based on duct hydraulic diameter is ranging from 10,000 to 30,000. A thin stainless steel foil of 0.05 mm thickness is used as heater and infrared thermography technique is used to obtain the local temperature distribution on the surface. The images are captured in the periodically fully developed region of the channel. It is observed that the heat transfer augmentations in the channel with 90 degrees saw tooth profiled ribs are comparable with those of 90 degrees continuous ribs. The enhancements caused by 60 degrees V-broken ribs are higher than those of 90 degrees continuous ribs. The effect of pitch to the rib height ratio (Ple) is not significant for channel with 60 degrees V-broken ribs for a given rib height to hydraulic diameter ratio (elD = 0.0625). (C) 2007
 
Publisher ELSEVIER SCIENCE INC
 
Date 2011-07-27T10:14:19Z
2011-12-26T12:56:43Z
2011-12-27T05:45:54Z
2011-07-27T10:14:19Z
2011-12-26T12:56:43Z
2011-12-27T05:45:54Z
2008
 
Type Article
 
Identifier EXPERIMENTAL THERMAL AND FLUID SCIENCE, 32(4), 997-1010
0894-1777
http://dx.doi.org/10.1016/j.expthermflusci.2007.11.015
http://dspace.library.iitb.ac.in/xmlui/handle/10054/7195
http://hdl.handle.net/10054/7195
 
Language en