Friction and heat transfer characteristics of flow through square duct with twisted tape insert
DSpace at IIT Bombay
View Archive InfoField | Value | |
Title |
Friction and heat transfer characteristics of flow through square duct with twisted tape insert
|
|
Creator |
RAY, S
DATE, AW |
|
Subject |
navier-stokes equations
pressure-drop correlations isothermal tubes |
|
Description |
This paper presents numerical prediction of characteristics of laminar, as well as, turbulent flow and heat transfer in a square sectioned duct inserted with a twisted tape, whose width equals the length of the duct side, The heat transfer characteristics are predicted under axially and peripherally constant wall heat flux conditions. As such, the flow and heat transfer are periodically fully developed in axial direction. Correlations for friction factor and Nusselt number are derived from the predicted data. The correlation for friction is compared with the experimental data, which are found to be in reasonably good agreement with each other, for both laminar and turbulent flows. (C) 2002 . .
|
|
Publisher |
PERGAMON-ELSEVIER SCIENCE LTD
|
|
Date |
2011-08-24T11:44:54Z
2011-12-26T12:56:53Z 2011-12-27T05:46:22Z 2011-08-24T11:44:54Z 2011-12-26T12:56:53Z 2011-12-27T05:46:22Z 2003 |
|
Type |
Article
|
|
Identifier |
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 46(5), 889-902
0017-9310 http://dx.doi.org/10.1016/S0017-9310(02)00355-1 http://dspace.library.iitb.ac.in/xmlui/handle/10054/10873 http://hdl.handle.net/10054/10873 |
|
Language |
en
|
|