Heat transfer augmentation for the flow of a viscous liquid in circular tubes using twisted tape inserts
DSpace at IIT Bombay
View Archive InfoField | Value | |
Title |
Heat transfer augmentation for the flow of a viscous liquid in circular tubes using twisted tape inserts
|
|
Creator |
AGARWAL, SK
RAO, MR |
|
Subject |
laminar-flow
prediction |
|
Description |
Isothermal and nonisothermal friction factors and mean Nusselt numbers for uniform wall temperature (UWT) heating and cooling of Servotherm oil (Pr = 195-375) were experimentally determined for their flow in a circular tube (Re-a = 70-4000) with twisted tape inserts (y = 2.41-4.84). Isothermal friction factors were found to be 3.13-9.71 times the plain tube values. The Nusselt numbers were found to be 2.28-5.35 and 1.21-3.70 limes the plain tube forced convection values based on constant flow rate and constant pumping power, respectively, for the minimum twist ratio tape. Correlations were developed for the prediction of isothermal friction factors and the Nusselt numbers. A correlation representing the effect of heat transfer on Friction Factors is also proposed. Copyright (C) 1996 .
|
|
Publisher |
PERGAMON-ELSEVIER SCIENCE LTD
|
|
Date |
2011-08-25T04:55:35Z
2011-12-26T12:56:55Z 2011-12-27T05:46:27Z 2011-08-25T04:55:35Z 2011-12-26T12:56:55Z 2011-12-27T05:46:27Z 1996 |
|
Type |
Article
|
|
Identifier |
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 39(17), 3547-3557
0017-9310 http://dx.doi.org/10.1016/0017-9310(96)00039-7 http://dspace.library.iitb.ac.in/xmlui/handle/10054/10901 http://hdl.handle.net/10054/10901 |
|
Language |
en
|
|