Experimental study of liquid carryover in a separator drum
DSpace at IIT Bombay
View Archive InfoField | Value | |
Title |
Experimental study of liquid carryover in a separator drum
|
|
Creator |
PRABHUDHARWADKAR, DM
MORE, RZ IYER, KN |
|
Description |
The phenomenon of carryover, i.e entrainment of liquid along with separated steam is observed in all the steam separators. Due to the risks, such as turbine blade erosion and radioactivity leakage, associated with it, it is desired to have an estimate of the carryover value. This is all the more important when the separation is only under the influence of gravity as proposed in some of the new generation natural circulation reactors. Experiments were carried out in an air-water facility at atmospheric conditions to characterize the entrainment in drums with ratio of the drum diameter to riser diameter varying from 1 to 6. Various parameters influencing the liquid entrainment were identified. The vapour superficial velocity and the drum diameter to riser diameter ratio were found to be the most influencing parameters. A dimensionless prediction correlation was evolved for the liquid entrainment and it was found to agree with previous works in the literature for drum to riser diameter ratio equal to 1. (C) 2009
|
|
Publisher |
ELSEVIER SCIENCE SA
|
|
Date |
2011-07-27T22:09:24Z
2011-12-26T12:58:32Z 2011-12-27T05:48:41Z 2011-07-27T22:09:24Z 2011-12-26T12:58:32Z 2011-12-27T05:48:41Z 2010 |
|
Type |
Article
|
|
Identifier |
NUCLEAR ENGINEERING AND DESIGN, 240(1), 76-83
0029-5493 http://dx.doi.org/10.1016/j.nucengdes.2009.09.018 http://dspace.library.iitb.ac.in/xmlui/handle/10054/7339 http://hdl.handle.net/10054/7339 |
|
Language |
en
|
|