Field application of phenol formaldehyde gel in oil reservoir matrix for water shut-off purposes
DSpace at IIT Bombay
View Archive InfoField | Value | |
Title |
Field application of phenol formaldehyde gel in oil reservoir matrix for water shut-off purposes
|
|
Creator |
BANERJEE, R
GHOSH, B KHILAR, K BOUKADI, F BEMANI, A |
|
Subject |
field application
gel oil reservoir phenol formaldehyde water shut-off |
|
Description |
A few wells from a major western India on-shore oil field are either on the verge of being shut in or have already been abandoned due to excessive water-cut (WCT) levels. Low injectivity and extreme temperatures (149C) make it difficult for water shut-off by conventional polymer gel injection. A water-thin monomer-based in situ gelation system has been developed and successfully tried in one of the wells that ceased production due to 100% WCT. The average production of 420 barrel of oil per day (BOPD) with less than 1% WCT, in the first year of production back in 1996, has declined to less than 8 BOPD (with 98% WCT) prior to shut-in in year 2002. A rise in the oil-water contact level in combination with a coning effect was diagnosed as a possible cause of the high WCT, which was later controlled by a newly developed gelant treatment. In fact, the average post-treatment production for the first 3 months was nearly 200 BOPD. Thereafter, production gradually stabilized in the neighborhood of 115 BOPD with a WCT of 48%. Cheap chemicals and a fast treatment method have resulted in a payback time span of 5 days and made an additional profit of U.S. $0.6 M. The water shut-off job resulted in an impressive commercial success; technical success, however, was less than satisfactory due to the fact that, in spite of using a water-thin monomeric solution, only 40% of the designed volume could be injected due to low injectivity resulting in an abnormal pressure build-up. In addition to the gel development and treatment experiences, this article describes in detail the results of further lab investigations carried out to identify the possible reasons causing injection failure.
|
|
Publisher |
TAYLOR & FRANCIS INC
|
|
Date |
2011-08-30T17:22:41Z
2011-12-26T12:59:04Z 2011-12-27T05:49:57Z 2011-08-30T17:22:41Z 2011-12-26T12:59:04Z 2011-12-27T05:49:57Z 2008 |
|
Type |
Article
|
|
Identifier |
ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 30(19), 1779-1787
1556-7036 http://dx.doi.org/10.1080/15567030701268476 http://dspace.library.iitb.ac.in/xmlui/handle/10054/12405 http://hdl.handle.net/10054/12405 |
|
Language |
en
|
|