EFFECT OF ORGANIC LOAD AND REACTOR HEIGHT ON THE PERFORMANCE OF ANAEROBIC MESOPHILIC AND THERMOPHILIC FIXED FILM REACTORS IN THE TREATMENT OF PHARMACEUTICAL WASTE-WATER

DSpace at IIT Bombay

View Archive Info
 
 
Field Value
 
Title EFFECT OF ORGANIC LOAD AND REACTOR HEIGHT ON THE PERFORMANCE OF ANAEROBIC MESOPHILIC AND THERMOPHILIC FIXED FILM REACTORS IN THE TREATMENT OF PHARMACEUTICAL WASTE-WATER
 
Creator SEIF, HAA
JOSHI, SG
GUPTA, SK
 
Subject pharmaceutical waste-water
mesophilic
thermophilic
fixed film reactor
 
Description Two anaerobic fixed film reactors were operated at 30-degrees-C and 55-degrees-C (as mesophilic and thermophilic reactors) with actual pharmaceutical wastewater to observe the effects of organic loading rate (OLR) and height of the reactor. Both the reactors were operated at OLR of 0.53, 0.85, 1.17 and 1.49 kg COD m-3 d-1 at HRT of 4.7 days. COD, TVA, SS, VSS, NH4+-N, PO43--P and SO4 were also measured. AMFFR showed better performance than ATFFR in terms of COD removal, and the effective height of the reactor was in the range of 30-90 cm.
 
Publisher TAYLOR & FRANCIS LTD
 
Date 2011-08-30T23:08:50Z
2011-12-26T12:59:13Z
2011-12-27T05:50:15Z
2011-08-30T23:08:50Z
2011-12-26T12:59:13Z
2011-12-27T05:50:15Z
1992
 
Type Article
 
Identifier ENVIRONMENTAL TECHNOLOGY, 13(12), 1161-1168
0959-3330
http://dspace.library.iitb.ac.in/xmlui/handle/10054/12497
http://hdl.handle.net/10054/12497
 
Language en