Note: Matching index technique for avoiding higher order mode resonance in accelerators: INDUS-2 accelerator as a case study
DSpace at IIT Bombay
View Archive InfoField | Value | |
Title |
Note: Matching index technique for avoiding higher order mode resonance in accelerators: INDUS-2 accelerator as a case study
|
|
Creator |
JAIN, V
BHANDARKAR, UV JOSHI, SC KRISHNAGOPAL, S |
|
Description |
Resonance between circulating beam frequencies and RF cavity Higher Order Modes (HOMs) of accelerators can lead to coupled-bunch instabilities. Shifting these HOMs to avoid the resonance is a topic of active interest. A study has been carried out for the accelerating cavities of the INDUS-2. For quantitative measure of deciding which modes have to be moved and by how much, we introduce a new index called the matching index (I-M), as a measure of how close a HOM is to the nearest beam mode. Depending on the value of IM, the operating scenarios are classified as safe and unsafe. (C) 2013 AIP Publishing LLC.
|
|
Publisher |
AMER INST PHYSICS
|
|
Date |
2014-10-16T12:44:38Z
2014-10-16T12:44:38Z 2013 |
|
Type |
Article
|
|
Identifier |
REVIEW OF SCIENTIFIC INSTRUMENTS, 84(8)
http://dx.doi.org/10.1063/1.4817185 http://dspace.library.iitb.ac.in/jspui/handle/100/15579 |
|