Note: Matching index technique for avoiding higher order mode resonance in accelerators: INDUS-2 accelerator as a case study

DSpace at IIT Bombay

View Archive Info
 
 
Field Value
 
Title Note: Matching index technique for avoiding higher order mode resonance in accelerators: INDUS-2 accelerator as a case study
 
Creator JAIN, V
BHANDARKAR, UV
JOSHI, SC
KRISHNAGOPAL, S
 
Description Resonance between circulating beam frequencies and RF cavity Higher Order Modes (HOMs) of accelerators can lead to coupled-bunch instabilities. Shifting these HOMs to avoid the resonance is a topic of active interest. A study has been carried out for the accelerating cavities of the INDUS-2. For quantitative measure of deciding which modes have to be moved and by how much, we introduce a new index called the matching index (I-M), as a measure of how close a HOM is to the nearest beam mode. Depending on the value of IM, the operating scenarios are classified as safe and unsafe. (C) 2013 AIP Publishing LLC.
 