Performance evaluation of coaxial thermocouple against platinum thin film gauge for heat flux measurement in shock tunnel
DSpace at IIT Bombay
View Archive InfoField | Value | |
Title |
Performance evaluation of coaxial thermocouple against platinum thin film gauge for heat flux measurement in shock tunnel
|
|
Creator |
IRIMPAN, KJ
MANNIL, N ARYA, H MENEZES, V |
|
Subject |
Thermocouple
Thin films Heat flux Hypersonic Shock tunnel Coaxial |
|
Description |
Data on surface heat flux is critical in all hypersonic missions due to the extent of risk and the penalty associated, when it is not properly accounted for. In the present study. an E-type coaxial thermocouple has been designed, fabricated, validated and benchmarked against a more established platinum thin film sensor. The study proves that coaxial thermocouples used in impulse facilities do not require cold junction compensation. The comprehensive study conducted in IIT Bombay Shock Tunnel (IITB-ST) has confirmed the performance, ruggedness and reliability of the coaxial thermocouple, ascertaining it to be an effective, impulse, heat flux sensor. (C) 2014 Elsevier Ltd. All rights reserved.
|
|
Publisher |
ELSEVIER SCI LTD
|
|
Date |
2016-01-15T04:37:47Z
2016-01-15T04:37:47Z 2015 |
|
Type |
Article
|
|
Identifier |
MEASUREMENT, 61,291-298
0263-2241 1873-412X http://dx.doi.org/10.1016/j.measurement.2014.10.056 http://dspace.library.iitb.ac.in/jspui/handle/100/17776 |
|
Language |
en
|
|