Electrochemical behaviour of pyridostigmine bromide-an anticolinergic drug at polyaniline/polypyrrole composite polymer electrode
NOPR - NISCAIR Online Periodicals Repository
View Archive InfoField | Value | |
Title |
Electrochemical behaviour of pyridostigmine bromide-an anticolinergic drug at polyaniline/polypyrrole composite polymer electrode
|
|
Creator |
Tiwari, D C
Jain, Rajeev Sharma, Shraddha |
|
Subject |
Composite polymer
Pyridostigmine bromide Polyaniline Polypyrrole Cyclic voltammetry Scanning Electron MicroscopyThermogravimetry Scanning Electron Microscopy Thermogravimetry |
|
Description |
319-324
A composite polymer surface coated on a tin oxide offers dramatic improvement in the stability and sensitivity of voltammetric measurement of pyridostigmine bromide as compared to individual tin oxide, polyaniline or polypyrrole coated electrode. A linear current response was achieved with a detection limit of 1x10⁻⁶ M. The stability and morphology of the polymer surfaces were determined by thermogravimetry and scanning electron microscopy respectively. The results suggest that composite polymer electrode is the best detector for pyridostigmine bromide (PB) at lower concentration. |
|
Date |
2009-01-20T04:43:11Z
2009-01-20T04:43:11Z 2008-07 |
|
Type |
Article
|
|
Identifier |
0971–457X
http://hdl.handle.net/123456789/2813 |
|
Language |
en_US
|
|
Publisher |
CSIR
|
|
Source |
IJCT Vol.15(4) [July 2008]
|
|