Indirect complexometric determination of mercury(II) using 3-acetyl-2-thiohydantoin as a selective masking agent
NOPR - NISCAIR Online Periodicals Repository
View Archive InfoField | Value | |
Title |
Indirect complexometric determination of mercury(II) using 3-acetyl-2-thiohydantoin as a selective masking agent
|
|
Creator |
Karthikeyan, J
Parameshwara, P Shetty, A Nityananda |
|
Subject |
Mercury(II)
3-Acetyl-2-thiohydantoin Complexometric titration |
|
Description |
493-496
A complexometric method for the determination of mercury(II) in presence of other metal ions is described based on the selective masking action of 3-acetyl-2-thiohydantoin towards mercury(II). Mercury(II) present in a given sample solution is first complexed with an excess of EDTA and the unreacted EDTA is titrated against standard lead nitrate solution at pH 5-6 (hexamine buffer) using xylenol orange as the indicator. A 0.5% solution of 3-acetyl-2-thiohydantoin is then added to displace EDTA from the Hg(II)-EDTA complex. The released EDTA is estimated. Reproducible and accurate results are obtained for 3.96 - 80 mg of mercury(II) with relative error less than ± 0.25% and coefficient of variation not more than 0.38%. The effects of various ions were studied. The method is used for the analysis of mercury in its synthetic mixtures of ions and in complexes. |
|
Date |
2009-01-22T06:26:23Z
2009-01-22T06:26:23Z 2008-09 |
|
Type |
Article
|
|
Identifier |
0971–457X
http://hdl.handle.net/123456789/2842 |
|
Language |
en_US
|
|
Publisher |
CSIR
|
|
Source |
IJCT Vol.15(5) [September 2008]
|
|