Influence of internal heat exchanger on performance of window AC retrofitted with R407C
NOPR - NISCAIR Online Periodicals Repository
View Archive InfoField | Value | |
Title |
Influence of internal heat exchanger on performance of window AC retrofitted with R407C
|
|
Creator |
Vijayan, R
Srinivasan, P S S |
|
Subject |
Air conditioning
Environmental chamber Internal heat exchanger R407C |
|
Description |
153-156
This paper presents experimental performance analysis of a window air conditioner (capacity, 1 TR) with and without an internal heat exchanger (IHE), along with performance comparison of R22 and R407C in the same AC. Use of IHE has increased coefficient of performance (COP) when running on R22 (5.86%) and R407C (6.3%). When retrofitting R22 systems with R407C, COP is found to drop with (6.26%) and without (6.64%) IHE. |
|
Date |
2009-01-30T04:17:33Z
2009-01-30T04:17:33Z 2009-02 |
|
Type |
Article
|
|
Identifier |
0022-4456
http://hdl.handle.net/123456789/2913 |
|
Language |
en_US
|
|
Publisher |
CSIR
|
|
Source |
JSIR Vol.68(2) [February 2009]
|
|