On-line biofouling control in the plate heat exchanger system through osmotic shock

NOPR - NISCAIR Online Periodicals Repository

View Archive Info
 
 
Field Value
 
Title On-line biofouling control in the plate heat exchanger system through osmotic shock
 
Creator Thiruppathi, K.
Lakshmi, P.
Saravanan, N.
Vinodha, S.
Kirubagaran, R.
 
Subject On-line monitoring
Biofouling control
PHE
 
Description 2158-2168
Cost effective control of biofouling is a challenging
task in the hazardous environment, especially in the nuclear power plants and
desalination plants. Biofouling control of plate heat exchangers was
investigated extensively using osmotic shock and the effectiveness of the
method was evaluated using microbiological data. Microbiological analysis were
carried out in the inlet and out let sea water and compared before and after
the osmotic shock. Prevention of scale deposits in the plate heat exchanger
system can benefit particularly nuclear power plants and desalination plants
and avoid unexpected production shut-downs resulting in substantial improvement
to power production in nuclear power plants. The water quality data showed
significant fouling control and improvement in the plate heat exchanger
operation. The plate heat exchanger system was examined for two different
duration (5 and 10 days) and two different temperature regime in order to test
system efficiency and to prevent the biofilm formation. A detailed analysis of
the entire treatment process was correlated with the microbiological
observation and functioning of the system.
 
Date 2016-06-30T06:05:03Z
2016-06-30T06:05:03Z
2014-11
 
Type Article
 
Identifier 0975-1033 (Online); 0379-5136 (Print)
http://hdl.handle.net/123456789/34587
 
Language en_US
 
Rights CC Attribution-Noncommercial-No Derivative Works 2.5 India
 
Publisher NISCAIR-CSIR, India
 
Source IJMS Vol.43(11) [November 2014]