Record Details

<strong>Measurements of dose rate for 10-16 keV Synchrotron X-ray photons at BL-16 beam line of Indus-2</strong>

Online Publishing @ NISCAIR

View Archive Info
 
 
Field Value
 
Authentication Code dc
 
Title Statement <strong>Measurements of dose rate for 10-16 keV Synchrotron X-ray photons at BL-16 beam line of Indus-2</strong>
 
Added Entry - Uncontrolled Name Sinhamahapatra, Debasis ; RRCAT, Department of Atomic Energy
Haridas, G. ; BARC, Department of Atomic Energy
Kumar, Pradeep ; RRCAT, Department of Atomic Energy
Ghodke, A D ; RRCAT, Department of Atomic Energy
Tiwari, M.K ; RRCAT, Department of Atomic Energy
Hannurkar, P.R ; RRCAT, Department of Atomic Energy
RRCAT, Indore, Department of Atomic Energy
 
Uncontrolled Index Term Radiation Dosimetry
synchrotron radiation; absorbed dose rate; dosimeter
 
Summary, etc. <span style="&quot;font-size: 11.0pt;" lang="&quot;EN-GB&quot;">Indus-2 is a 2.5 GeV electron synchrotron radiation source located at Raja Ramanna Centre for Advanced Technology (RRCAT), India. There is significant radiation exposure in the direct beam of synchrotron radiation due to its intense flux and low energy at synchrotron radiation beam line. In this paper, measurements of absorbed dose rate for mono chromatic synchrotron X-ray photon of energy ranging 10-16 keV is presented using various types of passive dosimeters, like CaSO<sub>4</sub>(Dy) TLDs, LiF :Mg,Ti (TLD-100), and Gafchromic film EBT-2 at microfocus X-ray fluorescence spectroscopy beam line (BL-16). The measured results are also compared with theoretically calculated values. It is observed that LiF :Mg,Ti (TLD-100), and Gafchromic film EBT-2 show 3-6 times more absorbed dose rates as compared to calculated values whereas CaSO<sub>4</sub>(Dy) TLD shows 10-20 times more absorbed dose rates.</span>
 
Publication, Distribution, Etc. Indian Journal of Pure & Applied Physics (IJPAP)
2016-04-27 09:35:15
 
Electronic Location and Access application/force-download
http://op.niscair.res.in/index.php/IJPAP/article/view/5276
 
Data Source Entry Indian Journal of Pure & Applied Physics (IJPAP); ##issue.vol## 54, ##issue.no## 4 (2016): Indian Journal of Pure & Applied Physics
 
Language Note en
 
Terms Governing Use and Reproduction Note Except where otherwise noted, the Articles on this site are licensed under Creative Commons License: CC Attribution-Noncommercial-No Derivative Works 2.5 India © 2015. The Council of Scientific &amp; Industrial Research, New Delhi.