Record Details

Design and Optimization of Displacement Measurement Eddy Current Sensor for Mass Production

Electronic Theses of Indian Institute of Science

View Archive Info
 
 
Field Value
 
Title Design and Optimization of Displacement Measurement Eddy Current Sensor for Mass Production
 
Creator Guganeswaran, S
 
Subject Sensors
Eddy Current Sensors
Displacement Measurement
Eddy Current Displacement Measurement Sensors
LC Oscillators
Eddy Currents
Eddy Current Sensing
Instrumentation
 
Description Eddy current (EC) based testing and measurement methods are well known in non-destructive testing (NDT) world. EC sensors are extensively studied and used for material health monitoring and its property measurement. Target displacement measurement is one of the well-known applications of EC method. The main advantage of EC sensor is its working capability in harsh environment like humidity, contamination etc. It is non-contact, rugged and requires less maintenance. The range and sensitivity of target displacement is mainly determined by the probe geometry and its construction method. Also displacement measurement depends upon geometry and electromagnetic (EM) properties of the target plate. Any variation of ambient temperature alters the EM properties of the probe as well as EM properties of the target. Thus, many parameters like geometry, EM properties and temperature involved in target displacement measurement. Hence, while using EC sensor for displacement measurement, it demands careful design and measurement procedure to achieve high sensitivity and high precision with low temperature drift. To achieve these, we present the following. 1) A temperature compensation technique 2) Optimization of probe geometry and its construction method to increase the range and sensitivity 3) Selection of suitable probe measurement parameter (Z, R, X) based on target material properties 4) Making the displacement measurement less sensitive to tolerance in probe construction parameter.
A temperature compensation technique for target displacement measurement, using a self-running LC oscillator has been presented. A sensing coil is energized by a Hartley oscillator. The oscillator voltage is maintained at a constant level by a closed loop feedback circuit and the average feedback current to the oscillator is measured for target displacement detection. The temperature drift of the feedback current is compensated by applying temperature compensation function (TCF) and this is verified experimentally. Cold rolled mild steel (carbon steel) is taken as a target material and the sensor is tested over a temperature range of 20 °C – 80 °C. It shows that the temperature drift is less than ±30 ppm/°C over 3 mm target displacement. To match all the sensor modules in mass production, components selection procedure is presented. To avoid mismatch across sensors in manufacturing process, the transistor based oscillator is modified with operational trans-conductance amplifier (OTA). The same temperature compensation formula (TCF) is applied to compensate the temperature drift of feedback current and achieved intended accuracy.
Geometry and construction parameters of the eddy current sensing probe is optimized for target displacement measurement using Ansoft Maxwell, electromagnetic design software. EC probe with
different geometry are analyzed in search of suitable geometry for target displacement measurement. Four shapes of commercially available core have been chosen for probe construction. For each shape of sensing probe, the radius and height of the probe is increased by 0 mm to 9 mm to find the effect of them on sensitivity and range of target displacement measurement. It has been observed that the probe with less height and maximum diameter has shown better performance. In addition to that, the probe geometry is optimized to achieve more sensitivity and range within the space available for probe mounting. It helps to utilize the available space effectively for probe design. Coil winding and mount-ing it inside the core window also important parameter in probe design. It has been observed that de-pressing the sensing coil inside the core window from sensing face by 3 mm decreases the sensitivity by 40 %. Hence, it is recommended to place the coil on the extreme end of the sensing face of the core. To know the effect of core permeability, it is varied from 1000 to 15000. It has been observed that it has no effect on sensitivity and measurement range.
Only optimizing the probe geometry and its construction method is not adequate for target displacement measurement. We know that the EC based displacement measurement is also target material dependent. Generally probe impedance is measured and then the temperature drift of the sensing coil resistance is compensated to know the target displacement. Most of the temperature compensation techniques use this compensation technique and it is shown that those are suitable for high conductivity targets like copper. Choosing Z for displacement measurement may not be only best choice for all target materials. The displacement can be measured also through either R or X of the probe. Choosing the proper probe parameter for a given target material will provide a less temperature drift for target displacement measurement. To know about this, a simulation has been made for target displacement measurement with target metal of μr = 1, relative permittivity εr =1, and temperature coefficient of resistivity ∝ = 0.004 K-1. The conductivity (σ) of the target is varied from 1×106 S/m to 62×106 S/m in the temperature range of 20 ℃ – 80 ℃. Now the simulation has been repeated by fixing  as a constant and varying target μr. The metal plate with  = 1×106 S/m, εr=1 and ∝ = 0.004 K – 1 is taken as a target and μr is varied from 100 to 10000. For both conductivity and permeability sweep analysis, the target displacement is measured as a function of Z, R and X independently. The temperature drift in displacement measurement is also analysed for the above temperature range. An experiment has been conducted with copper, stainless steel and mild steel as target metal in the temperature range of 20 ℃ – 80 ℃. The temperature drift is calculated when the displacement is measured as function of Z, R and X. Based on the results, we have identified that the target material relative permeability determines the selection of probe measurement parameter for target displacement measurement. Hence, knowing tar-get r alone suffice to select the probe measurement parameter (Z or R or X) for displacement measurement.
Optimizing the probe geometry, selecting the proper probe measurement parameter and temperature compensation technique suffice to provide a good sensitivity, range and low temperature drift for
a single probe. But in general, one of the mass produced probes is selected as a reference probe and it is calibrated against the ambient temperature and target displacement. And the calibration curves are loaded to all the probes. Matching the probe construction parameters to each other across the production patches is not possible in mass production. This makes the temperature compensation function and displacement calibration are different for every individual probes for displacement measurement. This degrades the measurement accuracy. A simulation has been performed with pot core with commercial tolerance. Using this, we have obtained 24 probes due to variations in 1) Individual and few combinational variations in core and coil dimensions 2) Core permeability variation and 3) relative position of the coil with respect to core. Finally, we have quantified the displacement error for each probe. We have identified the important probe dimensional parameters that have to be controlled precisely in mass production to improve the measurement accuracy. It shows error of 0.86 % in the displacement measurement when the relative reactance and relative displacement is used for measurement.
In practice, error in displacement measurement due to both the ambient temperature drift and the tolerance in probe construction parameter exist simultaneously. Hence, the combined error is computed for the target displacement range of 0 mm – 3 mm for the temperature range of 0 °C – 100 °C. The total error of less than 1 % is achieved for commercial standard probe tolerance. Finally, we have provided general factory production procedure and user calibration procedure of probe design to achieve cost effective displacement measurement with sensitivity and range with low temperature drift.
 
Contributor Gunasekaran, M K
 
Date 2017-11-14T09:31:03Z
2017-11-14T09:31:03Z
2017-11-14
2014
 
Type Thesis
 
Identifier http://etd.iisc.ernet.in/handle/2005/2754
http://etd.ncsi.iisc.ernet.in/abstracts/3617/G25986-Abs.pdf
 
Language en_US
 
Relation G25986