Title Stray current corrosion of copper sheathing and keel cooling pipe of a 36' trawler
 
Names Ravindran, K.
Date Issued 1968 (iso8601)
Abstract The results of investigations into the cause of an accelerated
corrosion of copper sheathing and keel cooling pipe of a 36' wooden
trawler are reported. The corrosion is attributed to the stray electric
currents originating from the electrical wiring system. The sources of
stray currents and the remedial measures have been suggested.
Genre Article
Identifier Fish Technol.5(2):96-100