<p style="text-align: justify;">Design and construction of ion-selective electrode based on a new Schiff base and its application in determination of copper(II) ions</p><p> </p>
Online Publishing @ NISCAIR
View Archive InfoField | Value | |
Authentication Code |
dc |
|
Title Statement |
<p style="text-align: justify;">Design and construction of ion-selective electrode based on a new Schiff base and its application in determination of copper(II) ions</p><p> </p> |
|
Added Entry - Uncontrolled Name |
Vardini, Mohammad Taghi ; Department of Chemistry, Tabriz Branch,
Islamic Azad University, Tabriz, Iran Valilue, Zahra ; Department of Chemistry, Tabriz Branch, Islamic Azad University, Tabriz, Iran Ghorbani Kalhor, Ebrahim ; Department of Chemistry, Tabriz Branch, Islamic Azad University, Tabriz, Iran Tabriz Branch, Islamic Azad University |
|
Uncontrolled Index Term |
Electrochemistry, Electroanalytical chemistry, Ion-selective electrodes, Schiff bases, Potentiometry, PVC-membrane, Copper |
|
Summary, etc. |
<p class="Abstract" style="text-align: justify;">A copper(II) selective sensor has been made from polyvinyl chloride matrix membrane based on the carrier, 2-(5-bromo-2-hyroxybenzylidineamino) pyridine 3-ol as an ionophore, <em>ortho</em>-nitrophenyl octyl ether (o-NPOE) as mediator solvent and sodium tetraphenylborate (NaTPB) as additive. The best performance is presented by membrane of composition of ionophore (Schiff base):PVC:<em>o</em>-NPOE:NaTPB of 3:33:63:1 (by weight). The membrane potential response is linear in the concentration range of 1.0×10<sup>-7</sup> to 1.0×10<sup>-2</sup> <em>M</em> with the Nernstian slope of 29.5±0.5 mV per decade of Cu<sup>2+</sup> and a detection limit of 7.4×10<sup>-8</sup> <em>M</em>. The response time of the sensor is very short; less than 10 s, and it can be used for at least 8 weeks without any difference in potential. The proposed copper(II) selective electrode displays excellent selectivity towards alkali, alkaline earth and transition metal ions and can be used in the <em>p</em>H range of 4-7. It has been successfully used as an indicator electrode for the determination of Cu(II) in water samples. The electrode has also been employed as an indicator electrode in titration of Cu<sup>2</sup><sup>+ </sup>with EDTA.<strong></strong></p> |
|
Publication, Distribution, Etc. |
Indian Journal of Chemistry -Section A (IJCA) 2020-12-16 15:22:51 |
|
Electronic Location and Access |
application/pdf http://op.niscair.res.in/index.php/IJCA/article/view/8561 |
|
Data Source Entry |
Indian Journal of Chemistry -Section A (IJCA); ##issue.vol## 55, ##issue.no## 1 (2016): INDIAN JOURNAL OF CHEMISTRY - SECTION A |
|
Language Note |
en |
|
Nonspecific Relationship Entry |
http://op.niscair.res.in/index.php/IJCA/article/download/8561/23968 |
|
Terms Governing Use and Reproduction Note |
Except where otherwise noted, the Articles on this site are licensed under Creative Commons License: CC Attribution-Noncommercial-No Derivative Works 2.5 India© 2015. The Council of Scientific & Industrial Research, New Delhi. |
|