Record Details

A comprehensive Analysis of Nanoscale Transistor Based Biosensor: A Review

Online Publishing @ NISCAIR

View Archive Info
 
 
Field Value
 
Authentication Code dc
 
Title Statement A comprehensive Analysis of Nanoscale Transistor Based Biosensor: A Review
 
Added Entry - Uncontrolled Name Kaur, Pawandeep ; lovely professional university
Buttar, Avtar Singh; IK Gujral Punjab Technical University, Kapurthala, Punjab, India
Raj, Balwinder ; National Institute of Technical Teachers Training and Research Chandigarh, India
 
Uncontrolled Index Term Nano electronics,biosensor,compound material
ISFET; Junctionless Dual gate Biosensor; Cylindrical/Surrounding Junctionless Biosensor; Semiconductor compound
 
Summary, etc. Imperative introduction of biosensor in the field of medicine, defence, food safety, security and environmental contamination detection acquired paramount attraction. Thus the foundation of the fame of biosensors in detecting wide scope of biomolecules in innumerable fields has driven researchers in advancement of biosensor and enhancing <br /> more updates in devices. Among all semiconductor-FET based biosensors grab attraction due to their miniaturization,mass production, ultra-sensitive in nature, improved lifetime, rapid response and reduce thermal budgets. In this review, field effect based biosensors sensitive to ions their principle model along with pros and cons of different structures. Various performance characteristics for semiconductor based biosensor are explored along with detection of label free analytes such as tuberculosis, glucose, antigen 85-B with ISFET. Following with comprehensive detail on MOSFET junction less Silicon based Dual Gate Biosensor with their design parameters for biosensing of neutral and charged analytes with results summarized in table. Drawbacks of dual gate structure introduce cylindrical structures summarized in table with device parameters and respective sensitivity. Role of analytes size in choosing the cavity width and position of analytes influence the sensitivity is recorded. Recent advancement on selectivity, sensitivity and switching results the gate and channel engineering thus compound semiconductor came in picture. In last section challenges with solution and importance of III-V compound channel as scope in biosensor with taking the benefits of fabrication of III-V compound MOSFETs. Semiconductor compound properties are summarized in table for various applications in recent use.
 
Publication, Distribution, Etc. Indian Journal of Pure & Applied Physics (IJPAP)
2021-03-24 12:11:03
 
Electronic Location and Access application/pdf
http://op.niscair.res.in/index.php/IJPAP/article/view/30896
 
Data Source Entry Indian Journal of Pure & Applied Physics (IJPAP); ##issue.vol## 59, ##issue.no## 4 (2021): Indian Journal of Pure & Applied Physics
 
Language Note en
 
Nonspecific Relationship Entry http://op.niscair.res.in/index.php/IJPAP/article/download/30896/465494925
http://op.niscair.res.in/index.php/IJPAP/article/download/30896/465495477
 
Terms Governing Use and Reproduction Note Except where otherwise noted, the Articles on this site are licensed under Creative Commons License: CC Attribution-Noncommercial-No Derivative Works 2.5 India © 2015. The Council of Scientific &amp; Industrial Research, New Delhi.