Record Details

<p><strong>Digital camera analysis of dichlorvos by phloroglucinol and quantitate with standard colour chart in environmental water matrices – an approach</strong></p>

Online Publishing @ NISCAIR

View Archive Info
 
 
Field Value
 
Authentication Code dc
 
Title Statement <p><strong>Digital camera analysis of dichlorvos by phloroglucinol and quantitate with standard colour chart in environmental water matrices – an approach</strong></p>
 
Added Entry - Uncontrolled Name Baskaran, Kamesh Viswanathan; Dr K.C. Patel Research and Development Centre, Charotar University of Science and Technology
Charotar University of Science and Technology (CHARUSAT) Research Grant
 
Uncontrolled Index Term Analytical Chemistry
DDVP, colour chart, phloroglucinol, semi-quantitative, digital camera analysis
 
Summary, etc. <p>Dichlorvos (DDVP) analysis using visible spectrophotometer, gas chromatography mass spectrometry and liquid chromatography mass spectrometry was studied extensively. The major drawback of all the method is requirement of standardisation, expensive and maintenance nature of instrument involvement. Since, many government has banned the use of DDVP, standardisation is quite challenging with single point standard method. In this study, using digital camera based colour analysis for DDVP was carried out to develop one-time multi standard colour chart. The analysis was carried out by alkaline degradation of DDVP to dichloro acetylaldehyde to react with phloroglucinol and producing distinct colour gradients from pale purple to dark brown. The colour chart was able to quantitate the limit of detection and limit of quantification of 6 µg/mL and 20 µg/mL respectively. The study was further experimented with real-time ground water with non-spiked and spiked DDVP samples for pre-concentration effect. The 1:1 linear relation was found with absorbance based spectrophotometer detection and digital camera image analysis to quantify around ppb level. This shows the colour analysis by human eye judgement is possible at certain level as semi-quantitate by strategical approach. In this paper, we have used the colour chart based digital camera detection of DDVP, which will be a viable alternate approach for analysing the environment samples.</p>
 
Publication, Distribution, Etc. Indian Journal of Chemistry -Section A (IJCA)
2021-09-22 10:50:13
 
Electronic Location and Access application/pdf
http://op.niscair.res.in/index.php/IJCA/article/view/46025
 
Data Source Entry Indian Journal of Chemistry -Section A (IJCA); ##issue.vol## 60, ##issue.no## 7 (2021): INDIAN JOURNAL OF CHEMISTRY- SECTION A
 
Language Note en
 
Nonspecific Relationship Entry http://op.niscair.res.in/index.php/IJCA/article/download/46025/465547752
 
Terms Governing Use and Reproduction Note Except where otherwise noted, the Articles on this site are licensed under Creative Commons License: CC Attribution-Noncommercial-No Derivative Works 2.5 India© 2015. The Council of Scientific &amp; Industrial Research, New Delhi.