Title Studies on Operational and Plant Parameters Affecting the Deposition of Charged and Uncharged Spray Droplets on Cabbage Plant Canopy
 
Creator Jyoti, Bikram
Mani, Indra
Kumar, Adarsh
Khura, Tapan Kumar
Sahoo, R N
Jha, G K
Shakil, N A
Parmar, Bhupendra Singh
 
Subject Charge to mass ratio
Electrode voltage
Electrostatic
Pesticides
Plants
 
Description 5-12
The existing method of pesticide application has resulted in wastage of chemicals and environmental pollution. Electrostatic spray charging system for impregnation of charge on spray droplets and its subsequent transfer to the precise plant target can mitigate the problems in conventional spraying. The operational parameters of spraying system and plant characteristics play an important role in deposition of spray droplets on plant canopy. In view of that, an experimental electrostatically spray charging system was developed to assess the deposition on plant surface. At electrode voltage (4kV), flow rate (250 ml/min) deposition was maximum for forward speed (1.0 km/h) and height of application (0.55 m) at charge to mass ratio of 1.53 mC/kg.
 