<p>A novel conductive sensor-based test method to measure longitudinal <br /> wicking of fabrics</p>
Online Publishing @ NISCAIR
View Archive InfoField | Value | |
Authentication Code |
dc |
|
Title Statement |
<p>A novel conductive sensor-based test method to measure longitudinal <br /> wicking of fabrics</p> |
|
Added Entry - Uncontrolled Name |
Suresh, S S ; Sona College of Technology Raja, D ; Sona College of Technology Thiyaneswaran, B ; Sona College of Technology Gobinath, R ; Sona College of Technology Sampath Kumar, S Kubera; Department of Chemical Engineering (Textile Technology) Panneerselvam, R G; Department of Fashion Technology, KCG College of Technology, Chennai 600117, India Senthilkumar, M ; Department of Textile Technology, PSG Polytechnic College, Chennai 600117, India Nil |
|
Uncontrolled Index Term |
Electrical conductivity sensor;Single jersey fabric;Static cling;Tribo-electric glass base;Wicking; Woven fabric |
|
Summary, etc. |
This paper reports the development of novel vertical wicking instrument which is specially designed to measure the wicking behavior of textile fabrics precisely. The instrument is designed using T-shaped test frame fabricated with tribo-electric fibre glass and electrical conductivity sensors. The developed electrical conductive sensors are capable to measure the time taken for the vertical wicking of water through inter-fibre capillaries with respect to height. The wet fabric allows the electrical current flow between two conductive points of sensor and enables the IoT controller circuit to monitor the time taken for wicking. To improve the accuracy of measuring the wicking behavior, tribo-electric fibre glass is used. The tribo electric fibre glass has electrostatic charges on its surface and induces static cling effect. Static cling is the tendency of light objects such as fabrics to stick (cling) to other objects owing to static electricity. The static cling effect attracts the fabric test sample to make it in contact with conductivity sensor array. The wicking process is carried out without causing obstruction to the movement of water through inter-fibre capillaries. The accuracy of the measured data obtained from the novel instrument is compared with the data of manual standard test procedure (R<sup>2</sup>> 0.97). The comparison shows that the developed instrument produces more reliable results. |
|
Publication, Distribution, Etc. |
Indian Journal of Fibre & Textile Research (IJFTR) 2022-07-12 00:00:00 |
|
Electronic Location and Access |
application/pdf http://op.niscair.res.in/index.php/IJFTR/article/view/54667 |
|
Data Source Entry |
Indian Journal of Fibre & Textile Research (IJFTR); ##issue.vol## 47, ##issue.no## 2 (2022): Indian Journal of Fibre & Textile Research |
|
Language Note |
en |
|
Nonspecific Relationship Entry |
http://op.niscair.res.in/index.php/IJFTR/article/download/54667/465576854 http://op.niscair.res.in/index.php/IJFTR/article/download/54667/465576989 http://op.niscair.res.in/index.php/IJFTR/article/download/54667/465576990 |
|