Evaluation of wind pressure on the low-rise buildings and surrounding terrainunder the influence of tornadolike vortex induced aerodynamic loads |
|
Added Entry - Uncontrolled Name |
Moizuddin, Mohammed ; Civil Engineering Department, RIMT University, Punjab 147 301 Goyal, Rajesh ; National Institute of Construction Management and Research, Delhi NCR Campus, New Delhi 110 037 Gupta, Nakul ; Department of Civil Engineering, GLA University, Mathura, Uttar Pradesh 281 406 Matsui, Masahiro ; Wind Engineering Research Centre, Polytechnic University, Tokyo 164-8678 |
|
Uncontrolled Index Term |
Tornado Simulator, Low rise building, Attached canopy, Surface pressure |
|
Summary, etc. |
Wind loading on buildings caused by straight line boundary layer winds has been thoroughly investigated in the past.The effects of vortex loading on structural projections will induce crosswind loads and torsional loads on low rise buildingwhich has severe dynamic resonant effect not only on the structural projections but also on over all structural elements of abuilding. These structural projections can be in the form of cantilever balconies, canopies, sunshades, overhangs,aesthetically projected elements. The purpose of each of these projections is different and designed to suit the convenienceof habitats. During the tornado, the damage of projections becomes flying debris due to the fatigue effect of fluctuatingpressure. In the present study,a model of low-rise buildings is tested under the influence of tornado-induced vortexes.Models were tested for F3 – F4 tornado for the wind speed 60m/s to 90m/s. Tornadoes of vortex core diameter 0.46 m to1.06 m in a smooth open terrain, simulations were carried out.A prototype of model of building in a scale of 1:400, actualdimensions of building is 20m x 20m x 10 m; the prototype model is prepared using flexi glass. An arrangement is made tostudy the effect of building on the ground terrain in surrounding region of building. Model was provided with pressuretapping to measure the surface pressure on all the walls and roof. |
|
Publication, Distribution, Etc. |
Indian Journal of Engineering and Materials Sciences (IJEMS) 2022-08-24 10:34:44 |
|
Electronic Location and Access |
application/pdf http://op.niscair.res.in/index.php/IJEMS/article/view/65764 |
|
Data Source Entry |
Indian Journal of Engineering and Materials Sciences (IJEMS); ##issue.vol## 29, ##issue.no## 3 (2022): IJEMS-JUNE 2022 |
|
Language Note |
en |
|
Terms Governing Use and Reproduction Note |
Except where otherwise noted, the Articles on this site are licensed under Creative Commons License: CC Attribution-Noncommercial-No Derivative Works 2.5 India © 2015. The Council of Scientific & Industrial Research, New Delhi. |
|