<strong>Gamma Passing Rate – Correlation with Patient Specific Quality Assurance Devices using Two Photon energies in Pelvic IMRT</strong>

Online Publishing @ NISCAIR

View Archive Info
 
 
Field Value
 
Authentication Code dc
 
Title Statement <strong>Gamma Passing Rate – Correlation with Patient Specific Quality Assurance Devices using Two Photon energies in Pelvic IMRT</strong>
 
Added Entry - Uncontrolled Name NIGAM, JITENDRA ; Department of Physics Invertis University Bareilly 243 123
KUMAR, PIYUSH ; SHRI RAM MURTI SMARAK INSTITUTE OF MEDICAL SCIENCES, BAREILLY 243202
SINGH, P P; DEPARTMENT OF PHYSICS Invertis University Bareilly-243 123
S, SILAMBARASAN N; SHRI RAM MURTI SMARAK INSTITUTE OF MEDICAL SCIENCES, BAREILLY 243202
S, NAVITHA ; SHRI RAM MURTI SMARAK INSTITUTE OF MEDICAL SCIENCES, BAREILLY 243202
 
Uncontrolled Index Term MEDICAL PHYSICS; RADIATION PHYSICS; INTERDISCIPLINARY
Gamma Analysis; IMRT; MatriXX; EPID; PSQA; Pelvis; Gamma Passing Rate; 6 MV &amp; 10 MV Photon Energy
 
Summary, etc. The effect on Gamma Passing Rate is studied by changing the Photon Energy in the Patient Specific Quality Assurancein Pelvic IMRT using EPID and MatriXX keeping PSQA device at Isocenter. Dose verification of 62 patients, sufferingfrom pelvic malignancies and treated with Intensity modulated radiation therapy (IMRT), with EPID and MatriXX usinggamma criteria of 3%/3 mm, 3%/2 mm, 2%/3 mm, 2%/2 mm and investigated the effect on Gamma Passing Rate (%GP) bychanging beam energy from 6 MV to 10 MV. The results demonstrated that the behavior of gamma passing rate decreases ascriteria is changed from 3%/3 mm to strict criteria. The mean gamma passing rate for 6 MV beam were (%GP±StandardDeviation σ) 99.64±0.81, 99.45±1.08, 97.57±2.12, 96.17±2.63 using the criteria 3%/3 mm, 3%/2 mm, 2%/3 mm, 2%/2 mmrespectively in EPID. For MatriXX, the mean %GP were 96.69±4.11, 93.85±5.31, 88.17±10.63, 82.2±12.28 respectively.For 10 MV, the mean (%GP±Std. Dev) were 99.64±0.81, 99.45±1.08, 97.57±2.12, 96.17±2.63 for in EPID, 96.69±4.11,93.85±5.31, 88.17±10.63, 82.2±12.28 for MatriXX respectively. Difference between %GP for 6 MV and 10 MV beam were-0.01, -0.11, 1.08, 1.61 with gamma criteria of 3%/3 mm, 3%/2 mm, 2%/3 mm, 2%/2 in EPID. For MatriXX, differencebetween %GP for 6 MV and 10 MV beam were -0.40, -0.24, 0.96, 1.62 respectively. It can be concluded that applying morestrict gamma criteria results in low gamma passing rate. There is marked difference in Gamma Passing Rate (%GP) withchange in photon energy.
 
Publication, Distribution, Etc. Indian Journal of Pure & Applied Physics (IJPAP)
2022-09-06 11:26:25
 
Electronic Location and Access application/pdf
http://op.niscair.res.in/index.php/IJPAP/article/view/55453
 
Data Source Entry Indian Journal of Pure & Applied Physics (IJPAP); ##issue.vol## 60, ##issue.no## 9 (2022): Indian Journal of Pure & Applied Physics
 
Language Note en
 
Nonspecific Relationship Entry http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465580361
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465580362
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465580363
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465580364
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465580365
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465580366
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465580368
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465580369
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465580370
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465580371
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465580372
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465580373
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465580374
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465580375
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465581354
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465581355
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465581356
http://op.niscair.res.in/index.php/IJPAP/article/download/55453/465581357
 
Terms Governing Use and Reproduction Note Except where otherwise noted, the Articles on this site are licensed under Creative Commons License: CC Attribution-Noncommercial-No Derivative Works 2.5 India © 2015. The Council of Scientific &amp; Industrial Research, New Delhi.