<p class="TitleMain"><strong>Monitoring mixed neutron-proton field near the primary proton and deuteron beams in spallation targets</strong></p>
Online Publishing @ NISCAIR
View Archive InfoField | Value | |
Authentication Code |
dc |
|
Title Statement |
<p class="TitleMain"><strong>Monitoring mixed neutron-proton field near the primary proton and deuteron beams in spallation targets</strong></p> |
|
Added Entry - Uncontrolled Name |
Tichý, P ; Joint Institute for Nuclear Research, Joliot-Curie 6, Dubna 141980, Russia Adam, J Baldin, A A Chudoba, P Furman, W I Gustov, S A Khushvaktov, J H Krása, A Majerle, M Mar’in, I I Solnyshkin, A A Suchopár, M Svoboda, J Svoboda, O Tyutyunnikov, S I Vrzalová, J Wagner, V Závorka, L Zeman, M |
|
Uncontrolled Index Term |
Accelerator-driven systems (ADS), Subcritical assembly, Neutron flux, Monte Carlo, Activation technique, High-energy beam, Phasotron, Nuclotron |
|
Summary, etc. |
<p class="Abstract">At the Joint Institute for Nuclear Research (JINR) we are involved in the Accelerator-Driven-System (ADS) research. We perform experiments with assemblies composed of a spallation target and a subcritical blanket irradiated with high-energy proton or deuteron beams that generate high-energy neutron fields by spallation and fission reactions. In this paper, three uranium assemblies are presented: Energy plus Transmutation (E+T), QUINTA and BURAN. We discuss the results of the E+T and QUINTA irradiations by 1.6 GeV deuterons and 660 MeV protons, respectively. We have focused on the regions close to the primary beam passage through the targets. The field has been measured using activation detectors of <sup>209</sup>Bi, <sup>59</sup>Co, and <sup>nat</sup>Pb. Monte Carlo simulations using MCNPX 2.7.0 have been performed and compared to the experimental results. We discovered that the field intensity near the primary beam is very dependent on the precision of the accelerator beam settings. Therefore, a Monte Carlo-based study of the influence of the uncertainty of primary proton beam parameters on experimental result accuracy of the QUINTA assembly has been carried out. The usage of MCNPX 2.7.0 in the future BURAN irradiations has been assessed.</p> |
|
Publication, Distribution, Etc. |
Indian Journal of Pure & Applied Physics (IJPAP) 2022-10-19 11:11:15 |
|
Electronic Location and Access |
application/pdf http://op.niscair.res.in/index.php/IJPAP/article/view/67638 |
|
Data Source Entry |
Indian Journal of Pure & Applied Physics (IJPAP); ##issue.vol## 58, ##issue.no## 4 (2020): Indian Journal of Pure & Applied Physics |
|
Language Note |
en |
|
Terms Governing Use and Reproduction Note |
Except where otherwise noted, the Articles on this site are licensed under Creative Commons License: CC Attribution-Noncommercial-No Derivative Works 2.5 India © 2015. The Council of Scientific & Industrial Research, New Delhi. |
|