Record Details

Radon and Thoron Exhalation Rate Measurements in Soil Samples Collected from the Vicinity of a Thermal Power Plant

NOPR - NISCAIR Online Periodicals Repository

View Archive Info
 
 
Field Value
 
Title Radon and Thoron Exhalation Rate Measurements in Soil Samples Collected from the Vicinity of a Thermal Power Plant
 
Creator Kumar, Pankaj
Kumar, Mukesh
 
Subject Soil samples
SMART RnDuo
Exhalation rates
 
Description 869-873
Radon mass and thoron surface exhalation rate of soil samples collected from the surrounding area of Harduaganj thermal power plant (HTPP), Aligarh is measured using an active radon/thoron monitor (SMART RnDuo). The radon mass exhalation rate values range from 27±1 to 100±3 mBq kg−1 h−1 with a mean value of 63±17 mBq kg−1 h−1. The thoron surface exhalation rate values vary from 1.0 ± 0.2 to 10±1 kBq m−2h-1 with a mean value of 5.7 ± 2.2 kBq m−2h-1. The mean values of radon mass and thoron surface exhalation rate are found to be higher than the worldwide mean values.
 
Date 2023-09-21T05:24:14Z
2023-09-21T05:24:14Z
2023-09
 
Type Article
 
Identifier 0975-0959 (Online); 0301-1208 (Print)
http://nopr.niscpr.res.in/handle/123456789/62553
https://doi.org/10.56042/ijpap.v61i10.2800
 
Language en
 
Publisher NIScPR-CSIR,India
 
Source IJPAP Vol.61(10) [October 2023]