KRISHI
ICAR RESEARCH DATA REPOSITORY FOR KNOWLEDGE MANAGEMENT
(An Institutional Publication and Data Inventory Repository)
"Not Available": Please do not remove the default option "Not Available" for the fields where metadata information is not available
"1001-01-01": Date not available or not applicable for filling metadata infromation
"1001-01-01": Date not available or not applicable for filling metadata infromation
Please use this identifier to cite or link to this item:
http://krishi.icar.gov.in/jspui/handle/123456789/38665
Title: | Determination of triazines and triazoles in grapes using atmospheric pressure matrix-assisted laser desorption/ionization high-resolution mass spectrometry |
Other Titles: | Not Available |
Authors: | Mahale V., Singh A., Phadke G.S., Ghanate A.D., Oulkar D.P., Banerjee Kaushik; Panchagnula V. |
ICAR Data Use Licennce: | http://krishi.icar.gov.in/PDF/ICAR_Data_Use_Licence.pdf |
Author's Affiliated institute: | ICAR::National Research Centre for Grapes |
Published/ Complete Date: | 2019-11-22 |
Project Code: | Not Available |
Keywords: | AP-MALDI Triazine and triazole pesticides High resolution accurate mass analysis |
Publisher: | Oxford University Press |
Citation: | Mahale V., Singh A., Phadke G.S., Ghanate A.D., Oulkar D.P., Banerjee Kaushik; Panchagnula V. (2017). Determination of triazines and triazoles in grapes using atmospheric pressure matrix-assisted laser desorption/ionization high-resolution mass spectrometry. Journal of AOAC International 100 (3): 640-646 |
Series/Report no.: | Not Available; |
Abstract/Description: | A chromatography-free atmospheric pressure matrix-assisted laser desorption/ionization high-resolution massspectrometry (AP-MALDI HRMS) method is described for the simultaneous and quantitative detection of triazines and triazoles in grapes. The analytes were detected reproducibly with high mass accuracy (mass error within 5 ppm) and further confirmed by collision-induced dissociation fragmentation in tandem MS. The LODs and LOQs forall the analytes were found to be in the nanogram per gram level (15–20 ng/g LOQ). Internal standard–normalized high-resolution accurate mass–extracted (HR-AM) peak intensities of the detected ions were used to generate the concentration response curves. Linearity (with R2 values around 0.99) was obtained for these curves within a concentration range of 20–200 ng/g of the individual analytes. The accuracy and precision of the method were further established using QC samples. Validation and performancecomparison of the AP-MALDI HRMS method with an existing standard method using LC with triple quadrupole MS was carried out (evaluating sensitivity, accuracy, precision, and analysis time) using 20 table-grape field samples after QuEChERS extraction. |
Description: | Not Available |
Type(s) of content: | Journal |
Sponsors: | Not Available |
Language: | English |
Name of Journal: | Journal of AOAC International |
Volume No.: | 100 |
Page Number: | 640-646 |
Name of the Division/Regional Station: | National Reference Laboratory |
Source, DOI or any other URL: | https://doi.org/10.5740/jaoacint.17-0047 |
URI: | https://doi.org/10.5740/jaoacint.17-0047 http://krishi.icar.gov.in/jspui/handle/123456789/38665 |
Appears in Collections: | HS-NRCG-Publication |
Files in This Item:
There are no files associated with this item.
Items in KRISHI are protected by copyright, with all rights reserved, unless otherwise indicated.