KRISHI
ICAR RESEARCH DATA REPOSITORY FOR KNOWLEDGE MANAGEMENT
(An Institutional Publication and Data Inventory Repository)
"Not Available": Please do not remove the default option "Not Available" for the fields where metadata information is not available
"1001-01-01": Date not available or not applicable for filling metadata infromation
"1001-01-01": Date not available or not applicable for filling metadata infromation
Please use this identifier to cite or link to this item:
http://krishi.icar.gov.in/jspui/handle/123456789/78064
Title: | Isothermal amplification assay for visual on-site detection of Staphylococcus aureus in Chevon. |
Other Titles: | Not Available |
Authors: | Priya GB, Agrawal RK, Milton AAP, Mendiratta SK, Singh BR, Kumar D, Kumar R, Mishra M |
ICAR Data Use Licennce: | http://krishi.icar.gov.in/PDF/ICAR_Data_Use_Licence.pdf |
Author's Affiliated institute: | ICAR-IVRI |
Published/ Complete Date: | 2021-01-01 |
Project Code: | Not Available |
Keywords: | Isothermal amplification assay for visual on-site detection of Staphylococcus aureus in Chevon |
Publisher: | Not Available |
Citation: | Not Available |
Series/Report no.: | Not Available; |
Abstract/Description: | The ability to rapidly detect pathogens in food is important from public health and food safety reasons. Traditional culture-based detection methods tend to be laborious, time consuming, technically demanding and may be limited due to their low sensitivity. Rapid detection methods for foodborne pathogens should be specific and sensitive to detect pathogens in low numbers. Sensitivity is important because a single pathogen present in food has the potential risk to cause infection. PCR and Real-time PCR are rapid, sensitive, and specific but require specific instruments and laboratory set-up. In the present study, a simple loop-mediated isothermal amplification (LAMP) assay was developed for rapid detection of Staphylococcus aureus. The LAMP assay was found to be ten times more sensitive than traditional end-point PCR with analytical sensitivity of 0.56 pg/μl and 5.6 pg/μl of DNA, respectively. In spiked chevon samples inoculated with S. aureus, the detection limit of LAMP and PCR assay was 3.3 × 105 CFU/g and 3.3 × 106 CFU/g, respectively, without enrichment. After enriching the samples for 6 h, the detection limit improved to 3.3 × 102 CFU/g and 3.3 × 104 CFU/g, respectively, indicating LAMP to be 100-fold more sensitive than PCR. The detection limit further improved to 3.3 CFU/g of meat after enrichment of 12 h. The developed LAMP was also found to be suitable when evaluated on field samples. The present study reports a simple LAMP assay for rapid visual detection of S. aureus which has potential for use in resource limited settings. |
Description: | Not Available |
ISSN: | Not Available |
Type(s) of content: | Article |
Sponsors: | Not Available |
Language: | English |
Name of Journal: | Food Biotechnology |
Volume No.: | 35(3) |
Page Number: | 1-16 |
Name of the Division/Regional Station: | Epidemiology division |
Source, DOI or any other URL: | 10.1080/08905436.2021.1941078 |
URI: | http://krishi.icar.gov.in/jspui/handle/123456789/78064 |
Appears in Collections: | AS-IVRI-Publication |
Files in This Item:
There are no files associated with this item.
Items in KRISHI are protected by copyright, with all rights reserved, unless otherwise indicated.